Optional Accessories - Graco 255963 Instructions And Parts

Double wall hopper
Hide thumbs Also See for 255963:
Table of Contents

Advertisement

Optional Accessories

See Accessories on page 24 for a list of all accessories
that can be used with double wall hoppers.
Immersion Heater Kit 256257
Ensure the outer cavity of the hopper is empty before
installing immersion heater to prevent oil or water mix-
ture from exiting hopper. Not for use in hazardous
environments.
For hazardous environments use the Hopper or
Hose Heat Circulation Kit 256273; see manual
312359.
Immersion heater kit 256257 can only be used when the
spray material is heated by a water mixture or oil in the
outer jacketed area of the hopper.
1. Remove plug (28) from side of hopper (D).
2. Apply thread sealant to immersion heater threads
(L) and screw immersion heater into hopper (D).
Vertically orientate wiring outlet.
3. Install bushing (302) in top of wiring outlet. Route
power cable (303) through bushing (302).
D
L
28
F
. 10: Immersion Heater
IG
4. Remove screws (HS) and immersion heater cover
(HC).
HC
HS
F
. 11: Immersion Heater Cover
IG
312747C
5. Connect white and black wires from cable (303) to
6. Connect green wire from cable (303) and green wire
7. Set thermostat knob (TK) to desired spray material
NOTE:
Set point (SP) is a "V" notch in the metal bracket at the
top of the thermostat dial. Maximum setting is 140°F
(60°C).
302
F
NOTE:
Ensure the cable (303) is located on top of the immer-
sion heater (L) before installing the cover (HC).
8. Install immersion heater cover (HC) with screws
white wires inside immersion heater box. Tighten
together with wire nuts (304).
inside immersion heater box. Tighten together with
with wire nut (304).
conditioning temperature. Align temperature setting
to set point (SP).
303
TK
L
. 12
IG
(HS). See F
. 11.
IG
Installation
SP
HC
11

Advertisement

Table of Contents
loading