Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Maximum altitude
Operating
Storage
Operating temperature derating
Up to 35°C (95°F)
35°C to 40°C (95°F to 104°F)
40°C to 45°C (104°F to 113°F)
Standard Operating Temperatures
Standard operating temperature
Continuous operation (for altitude less than
950 m or 3117 ft)
Expanded Operating Temperatures
Expanded operating temperature
Continuous operation
Specifications
0.26 G
at 5 Hz to 350 Hz (all operation orientations).
rms
1.88 G
at 10 Hz to 500 Hz for 15 min (all six sides tested).
rms
Specifications
Six consecutively executed shock pulses in the positive
and negative x, y, and z axes of 6 G for up to 11 ms.
Six consecutively executed shock pulses in the positive
and negative x, y, and z axes (one pulse on each side of
the system) of 71 G for up to 2 ms.
Specifications
30482000 m (10,0006560 ft)
12,000 m (39,370 ft)
Specifications
Maximum temperature is reduced by 1°C/300 m (1°F/547 ft)
above 950 m (3,117 ft).
Maximum temperature is reduced by 1°C/175 m (1°F/319
ft) above 950 m (3,117 ft).
Maximum temperature is reduced by 1°C/125 m (1°F/228 ft)
above 950 m (3,117 ft).
Specifications
10°C to 35°C (50°F to 95°F) with no direct sunlight on the
equipment.
Specifications
5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE:
Outside the standard operating
temperature (10°C to 40°C), the system can operate
continuously in temperatures as low as 5°C and as
high as 40°C.
For temperatures between 35°C and 40°C, derate maximum
allowable temperature by 1°C per 175 m above 950 m (1°F
per 319 ft).
Specifications
57