Startup
1. Fill the spool valve ports with compatible lubricant.
Consult with your material supplier to select an
acceptable lubricant. Regularly verify that lubricant
is present.
Spool Valve Ports
F
. 10: Top View of Metering Valve with Top Section
IG
Removed
2. Perform Ratio Check, page 23.
3. Install mixer and shroud.
4. Pressurize the A and B material feed systems con-
nected to the metering valve to prime the system.
See page 3 for maximum inlet feed pressures.
313876L
5. Dispense several full stroke shots until material is
air-free and has good shut-off at the nose.
NOTE: Very viscous, compressible materials may con-
tinue to drool after system is primed. Reduce flow rate
as required to produce air-free dispense.
NOTE: Very thin materials may require tilting the valve
greater than 45 degrees and dispensing shots until
material is air-free. Remove oil from cups before pro-
ceeding.
Startup
21