Startup; Dispensing Operation - Graco 1093 Setup & Operation

Control box
Table of Contents

Advertisement

Startup

Startup
NOTE: See HMI Operation starting on page 17 for
detailed HMI instructions.
1. Press the Control Power On button.
2. Navigate to the Metering Valve Control screen.
3. Press the Retract button.
NOTE: On Motor Driven models, when there is an
Emergency Stop condition or the system power is lost,
the shot selection resets to "0". The operator must then
select a shot.
4. Navigate to the Supervisor screen.
5. Press the Valve Type selection button to select your
configuration.
6. Navigate to the Shot Size screen.
7. Select a shot number.
8. Navigate to the Metering Valve Control screen.
NOTE: Upon power up, "Error Code 130 Position Mod-
ule is not Enabled" will be shown. Press the Retract
(Home) button to allow the dispense valve metering rod
connecting block to move to the reload position.
9. Press the Shot button to select Shot Mode.
10. Verify air pressure is set to 80 psi (5.6 bar).
11. Perform feed system startup procedure(s). See
Related Manuals on page 3.
12. Perform dispense valve startup procedure. See
Related Manuals on page 3.
16

Dispensing Operation

NOTE: See HMI Operation on page 17 for detailed HMI
instructions.
The foot switch, the "Start" button, and the optional Cus-
tomer Start Signal can be used to initiate shots. These
are referred to as start devices.
Perform a Shot
1. Navigate to the Metering Valve Control screen.
2. Press the Retract button.
3. Press the Shot button to select Shot Mode.
4. Press and release the start device to perform one
shot.
Dispense Continuously
The valve dispenses continuously until the end of the
stroke is reached.
1. Navigate to the Metering Valve Control screen.
2. Under Metering Valve Control, press the Retract
button.
3. Press the Continuous button.
4. On Motor Driven models, press and hold the start
device to dispense continuously. Release the start
device to stop dispensing and retract the metering
rods.
Retract Piston
1. Navigate to the Metering Valve Control screen.
2. Under Metering Valve Control, press the Retract
button.
Extend Piston
1. Navigate to the Metering Valve Control screen.
2. Under Metering Valve Control, press the Extend
button.
3A0261K

Advertisement

Table of Contents
loading

This manual is also suitable for:

1053

Table of Contents