Adjusting The Shot Size; Micrometer Pd44 Only; Lrt And Motor Driven Pd44 - Graco PD44 Operation & Maintenance Manual

Metering valves and feed systems
Hide thumbs Also See for PD44:
Table of Contents

Advertisement

Adjusting the Shot Size

Adjusting the Shot Size

Micrometer PD44 Only

1. Rotate the shot size locking ring counterclockwise
to loosen.
2. Rotate the shot size adjuster to adjust shot size.
3. Rotate the shot size locking ring clockwise to
tighten.
4. Dispense into waste container to test shot size.
5. Repeat until desired shot size is achieved.
22
6. If LED on the extend proximity switch is not illu-
minated, slide the proximity switch until the LED on
the proximity switch is illuminated.
Extend
Proximity
Switch
NOTE: The retract proximity switch (PX-RET) is factory
preset and does not need to be adjusted. If the lower
proximity switch is changed from the factory setting, see
the assembly drawings for more information on readjust-
ment. This switch is marked with a RET tag on the wire.

LRT and Motor Driven PD44

On LRT and Motor Driven PD44s, shot size is controlled
by the PD44 Control Box. See the PD44 Control Box
manual. See Related Manuals on page 3.
Retract
Proximity
Switch
313876L