Installation Manual; Installation Details; Connecting Pipe Length; Connecting Cables - Pioneer WYT Series Service Manual

Ductless mini split system air conditioner / heat pump
Table of Contents

Advertisement

9. Installation manual

9.1 Installation Details

Connecting pipe length

WYT009GLFI19RL
WYT009ALFI19RL
WYT012GLFI19RL
WYT012ALFI19RL
WYT018GLFI19RL
WYT024GLFI19RL
WYT036GLFI19RL
Outdoor unit
Pipe length is 15
m(59Inch) Max.
Indoor unit
Model
WYT009GLFI19RL
WYT009ALFI19RL
WYT012GLFI19RL
WYT012ALFI19RL
WYT018GLFI19RL
WYT024GLFI19RL
WYT036GLFI19RL

Connecting cables

The power cord should be selected according to the following specifications sheet.
Appliance Amps
Air Conditioner Service Manual
Model
Standard
length: m
(Inch)
5.0(19.7)
5.0(19.7)
5.0(19.7)
5.0(19.7)
5.0(19.7)
5.0(19.7)
5.0(19.7)
5
10
13
18
25
30
Pipe size(Inch)
Liquid
1/4
1/4
1/4
1/4
1/4
1/4
1/4
Refrigerant piping
Max. length: m (Inch)
A
15(59)
15(59)
15(59)
15(59)
15(59)
15(59)
15 (59)
Wire Size
AWG21/0.75 mm2
AWG18/1.0 mm2
AWG15 /1. 5 mm2
AWG14/1.6 mm2
AWG12/2.0 mm2
AWG10/2.5 mm2
Gas
3/8
3/8
3/8
3/8
3/8
1/2
5/8
Indoor unit
Pipe length is 15
m(59Inch) Max.
Outdoor unit
Additional refrigerant B
Calculation: ×g=Bg/m(A-5m)
20g/m
(20g/3.94)
20g/m(20g/3.94)
20g/m(20g/3.94)
20g/m(20g/3.94)
30g/m(30g/3.94)
30g/m(00g/3.94)
30g/m(30g/3.94)
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents