Complete kit for a pair of swing gates weighing up to 200kg per leaf/max. width 2.3m (12 pages)
Summary of Contents for CAME FA70230E
Page 1
SWING-GATE OPERATOR FA 00123 -E N INSTALLATION MANUAL FA70230E English...
Page 2
POWER ON ONSTANTLY CLEAN THE PHOTOCELLS GLASS COVERS USING A SLIGHTLY SE THIS PRODUCT ONLY FOR ITS EXPLICITELY INTENDED PURPOSE NY OTHER . CAME S. WATER MOISTENED CLOTH DO NOT USE SOLVENTS OR OTHER CHEMICAL PRODUCTS USE IS DANGEROUS IS NOT LIABLE FOR ANY DAMAGE CAUSED BY •...
2,75 Gate-leaf length (m) ⚠ We suggest you always fi t an electrolock onto swing gates for a more reliable closure. Technical data Type FA70230E Protection rating (IP) Power supply (V - 50/60 Hz) 230 AC Power supply motor (V)
Page 4
Description of parts 1. Cover 2. Post brace 3. Rubber shim 4. Gearmotor 5. Power supply terminal 6. Release hatch 7. Transmission arm 8. Joint arm 9. Gate brace 10. Mechanical stops Standard installation 1. Operator 2. Gearmotor 3. Flashing light 4.
Page 5
Applicative examples Fitted with standard jointed transmission-arm. Fitted with the STYLO-BD straight transmission-arm and slide rail. GENERAL INSTALLATION INDICATIONS ⚠ Only skilled, qualified staff must install this product. Preliminary checks ⚠ Before beginning, do the following: • check that the gate structure is sturdy enough, the hinges work efficiently and that there is no friction between the fixed and moving parts; •...
INSTALLATION ⚠ The following illustrations are just examples, in that the space available for fitting the operator and accessories varies depending on the overall dimensions. It is up to the installer to find the most suitable solution. The drawing show an operator fitted on the left. Install the operator on the right, symmetrically. Corrugate tube laying Lay the corrugated tubes you will need for the cables coming out of the junction pit.
Page 7
Mark the spots where the gate-post brace and gate brace will be fitted. The center-distances of the holes on the braces are shown in the Dimensions paragraph. Drill the anchoring points, fit the dowels or use plugs that will hold fast the screws. ...
Fastening the operator Fit the gearmotor into the gate.post brace and tighten the nuts and bolts. Fit the plug into the gearmotor's drive-shaft hole. Fasten the transmission arm to the drive-shaft using the slow-shaft washer and bolt. UNI 6593 UNI 5739 Ø...
Page 9
Release the gearmotor (see RELEASING THE GEARMOTOR), fit the driven arm to the gate brace as shown in the drawing. Ø 12 UNI 6592 Ø 12 UNI 6593 UNI 5739 Ø 6 M6x10 ⚠ WARNING! If no gate-leaf stops are in place, you must fit the mechanical stops. Fastening the mechanical stops Release the gearmotor.
Page 10
Establishing the limit-switch points With the gearmotor released and the gate-leaf closed, adjust the closing limit- switch grub screw by turning it clockwise or counterclockwise (). Tighten the nut to fasten the grub-screw (). In the same way, set the opening limit-switch on the other stop's grub screw ().
ELECTRICAL CONNECTIONS ⚠ Warning! Before working on the control panel, cut off the mains current supply and, if present, remove any batteries. 230 V AC gearmotor fi tted on the right (inside 230 V AC gearmotor fi tted on the left (inside view), with delayed closing.
FINAL OPERATIONS Perform the fi nal operations once all connections are complete and the system is up and running. RELEASING THE GEARMOTOR ⚠ This procedure must be done with the main power cut off . ⚠ Manually releasing the operator may result in uncontrolled movement of the gate, if this has any mechanical problems or is unbalanced. RELEASE LOCK...
INSTALLING AND CONNECTIONS FOR OUTER OPENING Following, are the only things that change compared to a standard installation: Fastening the brackets Establish where you will fit the gate brace and measure where the gate-post brace will fit. Make sure to respect the quotas shown in the drawing and table.
Fastening the mechanical stops Release the gearmotor. When opening. Entirely open the gate leaf. Mark the casing where the center of the arm is.(). Manually close the gate leaf. Place the mechanical stop under the casing. The mark on the case must match the groove on the stop, as shown().
Page 15
Electrical connections ⚠ Warning! Before working on the control panel, cut off the mains current supply and, if present, remove any batteries. 230 V AC gearmotor fi tted on the right (inside 230 V AC gearmotor fi tted on the left (inside view), with delayed closing.
TROUBLESHOOTING TROUBLES POSSIBLE CAUSES FIXES It neither opens • Power supply missing • Check whether the power is on nor closes • The gearmotor is stuck • Lock the gearmotor • The transmitter's battery is run down • Replace the batteries •...
Page 17
Extraordinary maintenance ⚠ The following table is for logging any extraordinary maintenance jobs, repairs and improvements performed by specialized contractors. Any extraordinary maintenance jobs must be done only by specialized technicians. Extraordinary maintenance log Fitter's stamp Name of operator Job performed on (date) Technician's signature Requester's signature...
☞ CAME S.p.A. applies a certified UNI EN ISO 14001 standard-compliant Environmental Management System at its premises to ensure the environment is safeguarded. Please help us safeguard the environment. At CAME it is fundamental to our operating and market strategies. Simply follow these brief disposal guidelines:...
Page 20
Came S.p.A. Came S.p.A. Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c 31030 Dosson di Casier Dosson di Casier 33079 Sesto al Reghena Sesto al Reghena Treviso Treviso - Italy Pordenone Pordenone - Italy (+39) 0422 4940 (+39) 0434 698111...