3.2.5.8
Embedded Display Port (eDP) signals
As described in the previous paragraph, the Intel
interface on DDI interface #0.
As a factory option, the module can be configured with this eDP interface available on COM Express connector AB, which allows supporting displays with a resolution
up 4096x2304 @ 60Hz.
Here following the signals related to eDP management:
eDP_TX0+/eDP_TX0-: eDP channel differential data pair #0.
eDP_TX1+/eDP_TX1-: eDP channel differential data pair #1.
eDP_TX2+/eDP_TX2-: eDP channel differential data pair #2.
eDP_TX3+/eDP_TX3-: eDP channel differential data pair #3.
eDP_AUX+/eDP_AUX-: eDP channel differential auxiliary channel.
eDP_HPD: eDP channel Hot Plug Detect. Active High Signal, +3.3V_RUN electrical level input with 100kΩ pull-down resistor.
eDP_VDD_EN: +3.3V_RUN electrical level output, Panel Power Enable signal. It can be used to turn On/Off the connected display.
eDP_BKLT_EN: +3.3V_RUN electrical level output, Panel Backlight Enable signal. It can be used to turn On/Off the backlight
eDP_BKLT_CTRL: this signal can be used to adjust the panel backlight brightness in displays supporting Pulse Width Modulated (PWM) regulations.
3.2.5.9
LPC interface signals
®
According to COM Express
specifications rel. 3.0, on the on COM Express connector AB there are 8 pins that can be used for implementation of Low Pin Count
(LPC) Bus or enhanced SPI (eSPI) interfaces, which are two multiplexed interfaces made available by the PCH. However, since LPC bus is needed for the
management of the Embedded microcontroller, then COMe-C55-CT6 module makes available only the LPC interface.
The following signals are available:
LPC_AD[0÷3]: LPC address, command and data bus, bidirectional signal, +3.3V_RUN electrical level.
LPC_CLK: LPC Clock Output line, +3.3V_RUN electrical level. Since only a clock line is available, if more LPC devices are available on the carrier board, then it is
necessary to provide for a zero-delay clock buffer to connect all clock lines to the single clock output of COM Express module.
LPC_FRAME#: LPC Frame indicator, active low output line, +3.3V_RUN electrical level. This signal is used to signal the start of a new cycle of transmission, or the
termination of existing cycles due to abort or time-out condition.
LPC_SERIRQ: LPC Serialised IRQ request, bidirectional line, +3.3V_RUN electrical level with 8k2Ω pull-up resistor. This signal is used only by peripherals requiring
Interrupt support.
COMe-C55-CT6