Omron S8VK-G Series Manual page 5

Switch mode power supply
Hide thumbs Also See for S8VK-G Series:
Table of Contents

Advertisement

Item
Efficiency
Voltage range *1
Frequency *1
Current
Input
Power factor
Leakage current
Inrush current *2 (for a
cold start at 25°C)
Rated output current
Boost current
Voltage adjustment range *3
Ripple & Noise
voltage *4
Input variation influence *8
Output
Load variation influence *7
Temperature variation influence 115 to 230 VAC input
Start up time *2
Hold time *2
Overload protection
Overvoltage protection *5
Additional
Series operation
functions
Parallel operation
Output indicator
Withstand voltage
Insulation
Insulation resistance
Ambient operating temperature *12
Storage temperature
Environment
Ambient operating humidity
Vibration resistance
Shock resistance
MTBF
Reliability
Life expectancy *9
Weight
Construction
Cooling fan
Degree of protection
Harmonic current emissions
EMI
EMS
Standards
Approved Standards
Conformed Standards
Marine Standards
SEMI
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on page 9 to 11 for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm
the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4. A characteristic when the ambient operating temperature is between –25 to 70°C.
*5. Refer to Overvoltage Protection on page 10 for the time when input voltage shuts off and input turns on again.
*6. The value is when both rated output voltage and rated output current are satisfied.
*7. 100 to 240 VAC input, in the range of 0 A to the rated output current
*8. This is the maximum variation in the output voltage when the input voltage is gradually changed within the allowable input voltage range at the rated output voltage and rated output current.
*9. Refer to Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance on page 22 for details.
*10. Safety Standards for a DC Input
The following safety standards apply to a DC input: UL 60950-1, cUR (CSA C22.2 No. 60950-1), EN 50178, EN 60950-1, and Lloyd's.
For a DC input, safety is ensured by an external fuse.
Select an external fuse that meets the following conditions.
S8VK-G240@@: 350 VDC min, 8 A
S8VK-G480@@: 350 VDC min, 12 A
*11. Clamp filter "ZCAT2035-0930" manufactured by TDK Corporation. or equivalent should be installed in the cable connected to the input - output terminals of S8VK-G series.
Noise filter "FN2080-10-06" manufactured by SCHAFFNER Corporation. or equivalent should be connected to the Input terminals of S8VK-G series.
*12. At −40 to −25°C, time will be required before the rated output voltage is output after the input voltage is input.
Also, the ripple noise value may exceed the value shown in the above table.
Power rating
Output voltage
24 V
230 VAC input *6
92% typ.
Single-phase, 85 to 264 VAC, 90 to 350 VDC *10
50/60 Hz (47 to 63 Hz)
115 VAC input *6
2.4 A typ.
1.3 A typ.
230 VAC input *6
230 VAC input, 100% load
0.9 min.
115 VAC input
0.23 mA typ.
0.33 mA typ.
230 VAC input
115 VAC input
16 A typ.
32 A typ.
230 VAC input
10 A
12 A
−10% to 15% (with V.ADJ) (guaranteed)
180 mVp-p max.
100 to 240 VAC input,
100% load *6
at 20 MHz of bandwidth
0.4% max.
0.8% max.
0.05%/°C max.
250 ms typ.
115 VAC input *6
230 VAC input *6
250 ms typ.
115 VAC input *6
44 ms typ.
44 ms typ.
230 VAC input *6
Yes, automatic reset
Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
Yes (For up to two Power Supplies, external diodes are required.)
Yes (Refer to Safety Precautions) (For up to two Power Supplies)
Yes (LED: Green), lighting from 80% to 90% or more of rated voltage
3.0 kVAC for 1 min. (between all input terminals and output terminals), current cutoff 20 mA
2.0 kVAC for 1 min. (between all input terminals and PE terminals), current cutoff 20 mA
1.0 kVAC for 1 min. (between all output terminals and PE terminals), current cutoff 20 mA
100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
−40 to 70 °C (Derating is required according to the temperature. Refer to Engineering Data) (with no condensation or icing)
−40 to 85°C (with no condensation or icing)
0% to 95% (Storage humidity: 0% to 95%)
10 to 55 Hz, 0.375 mm half amplitude for 2 h each in X, Y, and Z directions
2
150 m/s
, 3 times each in ±X, ±Y, ±Z directions
135,000 hrs min.
10 years min.
900 g max.
No
IP20 by EN/IEC 60529
Conforms to EN 61000-3-2
Conducted Emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B
Conforms to EN 61204-3 Class B, EN 55011 Class B
Radiated Emissions
Conforms to EN 61204-3 high severity levels
UL Listed: UL 508 (Listing)
UL UR: UL 60950-1 (Recognition)
cUL: CSA C22.2 No.107.1
cUR: CSA C22.2 No.60950-1
EN/VDE: EN 50178, EN 60950-1
ANSI/ISA 12.12.01
PELV (EN 60204-1, EN 50178)
EN 61558-2-16
Lloyd's register
Conforms to F47-0706 (200 to 240 VAC input)
240 W
48 V
5 A
6 A
350 mVp-p max.
at 20 MHz of bandwidth
290 ms typ.
290 ms typ.
43 ms typ.
*10 *11
S8VK-G
480 W
24 V
93% typ.
4.7 A typ.
2.3 A typ.
0.97 min.
0.3 mA typ.
0.49 mA typ.
16 A typ.
32 A typ.
20 A
10 A
24 A
12 A
230 mVp-p max.
470 mVp-p max.
at 20 MHz of bandwidth
at 20 MHz of bandwidth
0.4% max.
0.8% max.
0.05%/°C max.
380 ms typ.
260 ms typ.
40 ms typ.
50 ms typ.
Yes, automatic reset
1,500 g max.
48 V
5