1 Introduction
1.3

Components used

Prerequisites and restrictions
This application deals only with receiving and evaluating the data of the MV440. It
only provides a partial description of setting up the MV440.
The following components are required to implement the solution:
SIMATIC MV440 plus accessories (lens, ring light, lens protection)
PG/PC with browser, including 32-bit Java Runtime Environment
Depending on the application, the user must determine the suitable MV440
resolution, lens and lighting.
Hardware components
This application example was created with the following components:
Table 1-1
Component
SIMATIC S7-1200
CPU 1214 DC/DC/DC
CM 1243-5
communication module
SIMATIC S7-1500
CPU 1516-3 PN/DP
ASM 456
ET200ECO
ECOFAST connection
block
SIMATIC NET,
PROFIBUS ECOFAST
HYBRID CABLE
SIMATIC MV440 UR
CAB_CONF_ASM 456,
RF170C-READER_2M
Note
This document describes the automation solution with different S7 controller
types. You only need one of the above controllers to install and start up the
application example.
Software components
Table 1-2
Component
STEP 7 TIA Portal
MV Basics
Entry ID: 109757269,
V1.0,
No.
1
6ES7214-1AG40-
0XB0
1
6GK7243-5DX30-
0XE0
1
6ES7516-3AN01-
0AB0
1
6GT2002-0ED00
1
6ES7194-3AA00-
0AA0
1
6XV1830-7BH30
1
6GT3440-1LE10
1
6GT2891-4FH20
No.
1
6ES7822-1A.04-..
04/2018
Article number
Alternatively, you can use a
different S7-1200 CPU.
Only necessary in conjunction
with an S7-1200.
Alternatively, you can use a
different S7-1500 CPU.
Alternatively, you can use the
ET200 ECO connection block
M12 7/8".
(6ES7194-3AA00-0BA0)
Alternatively, you can use a
different MV420 / MV440.
The adapter cable 6GF3420-
0AC00-2CB must be used for
the MV420.
Article number
V14 SP1 or higher
Note
Note