Running via profibus as a technology objekt
Table of Contents

Advertisement

2 Engineering
6. When parameterizing the submodules, make sure to assign the same address
range to "I address" and "Q address".
7. Open an FC, FB or OB in which you want to call the Ident blocks.
8. In TIA Portal, navigate to "Instructions" > "Optional packages" > "SIMATIC
Ident". Drag the Ident blocks you require to the block you have just opened:
9. Assign the required values/tags to the parameter interfaces of the Ident blocks.
10. Download the user program and the hardware configuration to your S7 CPU.
To do this, select the S7 CPU in your project tree and then click "Download to
device".
MV Basics
Entry ID: 109757269,
V1.0,
04/2018
23