Search in the table at TVH and THL and enter the value that is found.
If the detected value is a number, check whether the completed STL is higher or equal to the value in
Is the STL value lower as specified in the table then the installation is not possible.
Solution: Start length to low, see for the minimum length in the top row of the table.
Restrictor size
Extra information
Install the air restrictor plate, see installation manual
Install adapter 100/150 direct on top of the fire
In case of wall terminal, install adapter 100/150 before
the last bend, incase of roof terminal just before the
In case of roof terminal (always size 100/150) install the
100/150 adapter just before the terminal.
Wall terminal 130/200
From the fire first an adjuster to 130/200 and 1 meter
130/200, after that reduce to 100/150 and everything
16 <
<
<
<
the table.
Is the found value X, then the installation is not possible.
Solution: Change the TVH or THL.
=
Value for the comma
=
Value behind the comma
terminal.
100/150.
Results
0,1
0,2
0,3
0,4
0,5
found value
....................................
....................... mm
mark