2.1.3

Clear the Drive Alarm

To clear the drive alarm, do the following:
1.
Check if the wiring of the drive is connected correctly and securely:
If it is, proceed to the next step.
If it is not, correct and tighten the wiring.
2.
Check if the setting value of parameter Drive Station Address is the same as
the drive station address of the machine tool:
If it is, proceed to the next step.
If it is not, modify the setting value of the parameter according to the
drive station address of the machine tool.
3.
Check if the polarity of port Servo Alarm is in NC status:
If it is not, modify the port polarity to NC status.

2.2 Set Drive Parameters

This operation is used to set drive parameters via the software after the system is
well connected to the servo drive.
Before setting drive parameters, ensure the system has been connected to the
hardware correctly.
To set drive parameters, do the following:
1.
Click System → Drive Param. Drive Param dialog box pops up: