2. Locate LP gas orifice spuds for top burners in the bag con-
taining literature included with the range. Three LP gas spuds
are stamped "88" and one "96."
3. Remove natural gas orifice spuds using a 7mm combination
wrench.
4. Install LP gas orifice spuds.
NOTE: Depending on model, the range cooktop may be
equipped with 4 standard burners or 3 standard burners and
1 power burner. Spud size/location remain the same.
Std burner 88
Power burner 96
5. Place the natural gas orifice spuds in the parts bag for future
use and keep with bag containing literature.
6. Reinstall burners, burner caps and burner grates.
A. Spud
B. Holder
Std burner 88
Std burner 88
To Convert Oven Burner
1. Open oven door and remove oven racks, oven tray, flame
spreader and set aside.
2. Lift oven burner. The orifice spud is behind the oven burner air
shutter.
A
3. Locate LP gas orifice spud stamped "56" in literature package
supplied with range.
4. Use a
" combination wrench and remove the natural gas
orifice spud.
5. Install the number "56" LP gas spud.
B
IMPORTANT: Do not over tighten.
6. Place natural gas oven burner spud in plastic parts bag along
with natural gas cooktop burner spuds for future use and
keep with bag containing literature.
7. Reinstall oven burner.
8. Reinstall oven racks, oven tray and flame spreader.
1. Refer to the "Make Gas Connection" section for properly
connecting the range to the gas supply.
2. Turn the manual shutoff valve in the gas supply line to the
open position.
3. Refer to the "Check Operation" section for proper burner
ignition, operation, and burner flame adjustments.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.
Checking for proper cooktop and oven burner flames is very
important. The small inner cone should have a very distinct
blue flame
is not as distinct as the inner cone. LP gas flames have a
slightly yellow tip.
4. Close the broiler door and turn the knob to "OFF".
5. Refer to the "Complete Installation" section to complete this
procedure.
A. Air shutter
A
A. LP oven orifice spud stamped with "56"