3. Locate Propane gas orifice spud stamped "58" in the bag
containing literature supplied with the range.
4. Use a 3/8" (1 cm) combination wrench to remove the
Propane gas orifice spud.
5. Install the number "58" Propane gas spud.
A
A. Propane oven orifice spud stamped with "58"
IMPORTANT: Do not overtighten.
6. Place Natural gas oven burner spud in plastic parts bag
along with Natural gas cooktop burner spuds for future use
and keep with the bag containing literature.
7. Reinstall oven burner.
8. Reinstall oven racks, oven tray, and flame spreader.

Complete Conversion

1. Refer to the "Make Gas Connection" section for properly
connecting the range to the gas supply.
2. Turn the manual shut-off valve in the gas supply line to the
open position.
3. Refer to the "Electronic Ignition System" section for proper
burner ingestion, operation, and burner flame adjustments.
IMPORTANT: You may have to adjust the "LOW" setting for
each cooktop burner.
Checking for proper cooktop and oven burner flames is very
important. The small inner cone should have a very distinct
blue flame 1/4" to 1/2" (6.4 mm to 13 mm) long. The outer
cone is not as distinct as the inner cone. Propane gas flames
have a slightly yellow tip.
4. Close the broiler door and press the CANCEL/OFF pad.
5. Refer to the "Complete Installation" section to complete this
procedure.
14

Natural Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shut-off valve to the "closed" position.
A
A. Gas supply line
B. Manual shut-off valve "closed" position
C. To range
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1. Open broiler door, and remove broiler rack. The gas pressure
regulator is located in the back right-hand corner of the
broiler compartment.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.