Download Print this page
Nordson Prodigy HDLV Instruction Sheet
Nordson Prodigy HDLV Instruction Sheet

Nordson Prodigy HDLV Instruction Sheet

Circuit board replacement
Hide thumbs Also See for Prodigy HDLV:

Advertisement

Quick Links

t
Prodigy
HDLV
Circuit Board Replacement
WARNING: Allow only qualified
personnel to perform the following tasks.
Follow the safety instructions in this
document and all other related
documentation.
WARNING: Shut off and lock out system
electrical power before performing the
following tasks. Failure to observe this
warning may result in personal injury.
Replacing the Circuit Board
1. See Figure 1. Close the air supply valve and
trigger the guns to relieve air pressure.
Figure 1
Turning Off Air and Power
E 2006 Nordson Corporation
t
Pump
Instruction Sheet
P/N 1058046B02
CAUTION: Observe the following
cautions when removing or installing the
circuit board. Failure to observe these
cautions may result in equipment
damage.
S
The circuit board is an electrostatic sensitive
device (ESD). Wear a grounding wrist strap
connected to the pump panel or other
ground.
S
Turn off and relieve air pressure to the
pumps before removing the circuit board.
S
Do not disconnect the air tubing from the
circuit board. The transducers are very
delicate and will break if the air tubing is
removed.
2. Turn off power to the pump panel. Disconnect
the pump panel from its power source.
O
I
Part 1058046B02

Advertisement

loading

Summary of Contents for Nordson Prodigy HDLV

  • Page 1 1. See Figure 1. Close the air supply valve and 2. Turn off power to the pump panel. Disconnect trigger the guns to relieve air pressure. the pump panel from its power source. Figure 1 Turning Off Air and Power E 2006 Nordson Corporation Part 1058046B02...
  • Page 2 Prodigy HDLV Pump Circuit Board Replacement Replacing the Circuit Board (contd) CAUTION: Do not disconnect the air 6. See Figure 3. Connect the new circuit board’s eight transducer air tubes to the appropriate tubing from the circuit board. The fittings on the pump control manifold(s).
  • Page 3 Prodigy HDLV Pump Circuit Board Replacement Pump 2 Manifold Pump 1 Manifold Top View Top View Bottom View Bottom View Figure 3 Circuit Board-to-Pump Control Manifold Connections E 2006 Nordson Corporation Part 1058046B02...
  • Page 4 A, B, and C calibration numbers from the sticker on the pump control manifold. Issued 11/08 Original copyright date 2005. Nordson and the Nordson logo are registered trademarks of Nordson Corporation. HDLV and Prodigy are trademarks of Nordson Corporation. E 2006 Nordson Corporation...