WARNING
Allow only qualified personnel to perform the following
tasks. Follow the safety instructions in this document
and all other related documentation.
Remove the Packing Gland
The air motor lockout valve is item 1 in Figure 1.
Set air motor
lockout valve
to . . .
ON
1.
See Figure 1. Operate air motor
until coupling (5) is accessible.
OFF
2.
Place elevator in NEUTRAL
position and shut off compressed
air supply (1).
3.
Depending upon the system,
perform one of the following:
S
Open ball valve (2).
S
Open bleed valve (3) no more
than three turns.
than three turns.
4.
Bleed hydraulic pressure through
valve and guns. Leave valve open.
5.
Remove screws (4) securing
coupling (5) to coupling shaft (10)
and plunger rod (9).
6.
Drain solvent chamber cup (6).
7.
Set air motor regulator to 0 bar/psi.
ON
8.
Using minimal air pressure, cycle
air motor to lower plunger rod (9).
9.
Cycle air motor to raise air
motor shaft.
OFF
10. Remove solvent chamber cup (6)
from upper collar (8).
11. Disconnect tubing (11) from
fittings (12).
12. Remove screws (7) from upper
collar (8).
13. Insert screwdrivers into pry
slots (13). Pry upper collar (8) off
of pump body (14). If collar cannot
be removed from pump body,
perform the following:
a.
Insert two screws (7) into
upper collar threaded holes as
shown.
b.
Alternate tightening screws (7)
to remove packing gland
assembly.
14. Loosen set screw (15) and remove
collar (8) from packing gland (16).
15. Remove fittings (12) from packing
gland (16).
E 2007 Nordson Corporation
Stainless Steel Packing Gland Replacement
Then . . .
Issued 10/07
1
2
3
DO NOT OPEN
BLEED VALVE (3)
MORE THAN 3 TURNS.
4
5
6
7
8
11
12
13
14
Figure 1
Removing the Packing Gland
Rhinor XD2
10
9
OPTIONAL PACKING
7
GLAND REMOVAL
11
12
16
15
Instruction Sheet 1081653A