Listing And Code Approvals; Appliance Certification; Mobile Home Approval; Glass Specifications - Harman P35i Owner's Manual

Pellet insert
Table of Contents

Advertisement

2 2

Listing and Code Approvals

A. Appliance Certification
MODEL:
P35i Pellet Insert
LABORATORY: OMNI Test Laboratories, Inc
REPORT NO.
135-S-25-6.2
TYPE:
Solid Fuel Room Heater / Fireplace
Insert
STANDARD(s):
ASTM E 1509-12, ULC-S628-93, EPA
Method 28 & 5G
The P35i Pellet Insert is certified to
comply with 2015 particulate emission
standards. Not approved for sale after
May 15, 2020.
NOTE: This installation must conform with local codes.
In the absence of local codes you must comply with the
ASTM E1509-2004, ULC S628-93, (UM) 84-HUD
B. Mobile Home Approved
This appliance is approved for Installation in mobile/
manufactured homes. The structural integrity of the
mobile home floor, ceiling and walls must be maintained.
The appliance must be properly grounded to the frame of
the mobile home, and must never be installed in a room
designated for sleeping. The unit must have provisions for
an outside air source when installed in a mobile home.
C. Glass Specifications
This appliance is equipped with 5mm mirrored ceramic
glass. Replace glass only with 5mm mirrored ceramic glass.
Please contact your dealer for replacement glass if needed.
D. Electrical Rating
120 VAC, 60 Hz, 3.6 Amps (Start-up); avg. 1.5 Amps
(Normal Run)
4
Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20
E. BTU & Efficiency Specifications
EPA Certification Number:
EPA Certified Emissions:
*LHV Tested Efficiency:
**HHV Tested Efficiency:
***EPA BTU Output:
****BTU Input
Vent Size:
Hopper Capacity:
Fuel
* Weighted average LHV efficiency using data collected
during EPA emissions test.
**Weighted average HHV efficiency using data collected
during EPA emissions test.
***A range of BTU outputs based on EPA Default Efficiency
and the burn rates from the low and high EPA tests.
****Based on the maximum feed rate per hour multiplied by
approximately 8,600 BTU's which is the average BTU's from
a pound of pellets.
This wood heater has a manufacturer-set minimum low burn
rate that must not be altered. It is against federal regulations
to alter this setting or otherwise operate this wood heater
in a manner inconsistent with operating instructions in this
manual.
This wood heater needs periodic inspection and repair for
proper operation. It is against federal regulations to operate
this wood heater in a manner inconsistent with operating
instructions in this manual.
964-14
1.5 g/hr
78%
69.5%
9,600 - 28,800
12,800 - 38,400
4 Inch
41 Lbs (19-1/2" Hopper)
62 Lbs (23-1/2" Hopper)
Wood Pellet
3-90-775

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents