Factory Plate; Transport And Storage; Inspection; Transport - ABB FAM3200 Series Commissioning Instruction

Armored variable area purgemeter
Hide thumbs Also See for FAM3200 Series:
Table of Contents

Advertisement

4.1.2

Factory plate

In addition to the name plate, the factory plate is also on the
meter tube of the flowmeter.
Ser.-No.: D10A32_5 / 123456
8
1/2"NPT / 100 bar
7
Material: 1.4571
6
Manufactured: 2015 PED: SEP
ABB Automation Products GmbH
5
37079 Göttingen - Made in Germany -
4
Tmed = -30°C...+100°C
Fig. 4:
Factory plate
1 CE mark 2 Serial number of the sensor
3 Reason for exception under article 4, paragraph 3 of the Pressure
Equipment Directive
4 Measuring medium temperature
5 Manufacturer's address 6 Year of construction
7 Material of the pressure-bearing part (wetted part)
8Nominal diameter / nominal pressure rating
The reason for exception according to article 4 paragraph 3 of
the Pressure Equipment Directive is specified under PED.
The pressure equipment is classified in the SEP (= Sound
Engineering Practice) "Good Engineering Practice" category.
NOTE
The measuring medium temperature specified on the factory
plate only applies for the meter tube.
Depending on the device design (options, Ex approval), the
permissible measuring medium temperature may deviate
from the specified range.
The information on the permissible measuring medium
temperature (T
) can be found in chapter "Specifications"
med
on page 16.
5

Transport and storage

5.1

Inspection

Check the devices immediately after unpacking for possible
damage that may have occurred from improper transport.
1
Details of any damage that has occurred in transit must be
2
recorded on the transport documents.
All claims for damages must be submitted to the shipper
3
without delay and before installation.
5.2

Transport

— The center of gravity of some devices is not at the center
of the equipment.
G11967
— Use the any available attachment points on the device for
transport.
— Ensure that all transport locking devices are available and
correctly installed.
— Transport packaging marked visibly with the note "Caution
Glass".
5.3

Storage

Bear the following points in mind when storing devices:
— Store the device in its original packaging in a dry and
dust-free location.
— Observe the permitted ambient conditions for transport
and storage.
— Avoid storing the device in direct sunlight.
— In principle, the devices may be stored for an unlimited
period. However, the warranty conditions stipulated in the
order confirmation of the supplier apply.
The ambient conditions for the transport and storage of the
device correspond to the ambient conditions for operation of
the device.
Adhere to the device data sheet!
5.4

Returning devices

For the return of devices, follow the instructions in the chapter
"Returning devices" on page 15.
FAM3200 | CI/FAM3200-EN Rev. B 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fam3220Fam3225Fam3250Fam3255

Table of Contents