Configuration
Internal DHCP Server
The DHCP server is only enabled on the LAN interface.
By default, Internal DHCP Server is set to Enabled.
This means that the IP address settings are set automatically by the Wireless Bolt IoT
internal DHCP server.
IP Address Range
When the Wireless Bolt IoT is enabled, you can still use static IP addresses within the remaining IP
address range. The devices assigned to these IP addresses can set Wireless Bolt IoT as the default
gateway and DNS server.
The internal DHCP server address host ID range is by default set to start at 100 and stop at 200.
You can set a preferred host ID range.
®
Anybus
Wireless Bolt IoT
User Manual
If there is already a DHCP server on the network, you must set the Internal DHCP Server
setting to Disabled.