11. CLEANING

Tip
Your ANIMO dealer will gladly advise you about their service and
maintenance o ers.
Depending on pellet consumption, a message prompting cleaning of the stove
appears on the display in regular intervals. This message can be acknowledged
on the Touch Display, while continuing operation. Perform a cleaning cycle at
the next opportunity.
Subsequently, reset the counter in the SETTINGS menu / RESETS submenu, as
per operating instructions of TOUCH DISPLAY.
Tip
The message will only stop reappearing once you have reset the feed volume
in the SETTINGS / Resets menu.
Note
Your stove must be switched o
work is performed. Only work on the unit when the mains plug has been
disconnected.

Cleaning the convection air openings

Vacuum clean any dust deposits from the convection air openings at regular
intervals.
The stove should be cleaned thoroughly prior to the start of the heating season
to prevent excess odour.
Note
To prevent your stove from overheating of the internal components, do never
cover the convection ns!

Combustion air - intake

If necessary, please also clean the air intake with a hoover.
Note
Only when the stove is cold! You could vacuum out embers – FIRE RISK!

Cleaning the pellet container

Do not re ll the completeley emptied container immediately; remove the
residues (dust, chippings etc.) from the bottom of the container. The unit must
be disconnected from the mains!

Bearings

annually
All built in bearings (pellet screw, turning grid) should be checked. Clean or
replace bearings depending on condition.

Checking seals

(annually)
Check the condition of the seals at least once a year. Repair or replace seals
depending on condition.
Note
Only intact seals ensure your stove works perfectly!
Tip
You will nd the seals and sealing kit in the spare part overview.
22
and cooled before any maintenance

Cleaning the flue gas channels

The ue gas channels are situated beside the combustion chamber.
Preparation Aduo
Open the combustion chamber door.
Remove the convection ns by using the lifting assistance.
2.
1.
Loosen the two wing screws.
Lift the side panel to remove it.
Preparation Aduo Multi Air
Open the combustion chamber door.
Remove the convection ns by using the lifting assistance.
2.
1.
Remove the 2 hexagonal screws.
Lift the side panel to remove it.
3.
4.
3.
4.
#8