Drain Motor (Variable Speed)

This test will check the wiring to the drain motor and the drain
motor itself. The following items are part of the drain motor
circuit.
■ Harness/Connection
■ Drain Motor (Variable Speed)
■ Control Board
Test Procedure
1. Verify that drain hose or drain path is not obstructed.
Check for blockage from sump check valve to customer's
plumbing. Check for plugged garbage disposal or disposal
plug not knocked out. Check drain loop, stuck check valve,
or for plugged hoses. Repair as needed.
2. Check the drain motor and electrical connections by
performing the Service Diagnostic Cycle. The following
steps assume that this step was unsuccessful.
3. Unplug dishwasher or disconnect power.
4. Remove outer door panel to access control board.
Strip Circuit – Wash & Drain Motors (Variable Speed)
For Service Technician Use Only
Kenmore Elite 2013 Stainless Steel Tall Tub Dishwasher
5. Visually check that connector P5 is inserted all the way
into the control board.
¾ If visual checks pass, go to step 6.
¾ If visual checks fail, reconnect P5 and repeat step 2.
6. Visually check that the drain motor connector is inserted
all the way into the motor.
¾ If visual checks pass, go to step 7.
¾ If visual checks fail, reconnect motor connector and
repeat step 2.
7. Check the harness between the control board and drain
motor for continuity.
¾ If there is continuity, go to step 8.
¾ If there is no continuity, repair or replace harness as
needed.
8. Check the drain motor windings. Disconnect the P5
from the control board. With an ohmmeter, verify the
resistance values as show below.
Motor Harness
P5, Pins 4 & 5
P5, Pins 5 & 6
P5, Pins 6 & 4
¾ If the values are outside the range, open, or
inconsistent from winding to winding, replace the wash
motor.
¾ If the values are within the ranges listed, replace the
control board.
9. Unplug dishwasher or disconnect power.
10. Reassemble all parts and panels.
11. Plug in dishwasher or reconnect power.
TESTING
Windings (ohms)
81-95 ohms
81-95 ohms
81-95 ohms
5-15