Fastaddress - Bosch BasicDome Series Instruction Manual

Indoor pendant & in-ceiling models
Hide thumbs Also See for BasicDome Series:
Table of Contents

Advertisement

Indoor Pendant & In-ceiling Models | Instruction Manual | FastAddress
4

FASTADDRESS

The following is an example of FastAddressing a
BasicDome (ID number 26636, logical camera #3).
1. Call the camera up to the screen you are viewing
(i.e. CAMERA-3-ENTER).
2. Press ON-999-ENTER to display the screen shown
in FIGURE 2.
Figure 2: Fast Address
Any camera without a FastAddress will display the
screen in FIGURE 2 when the ON-999-ENTER
command is used. Make sure you are viewing the
camera that you want to program.
If the camera's FastAddress is the same as the keyboard
camera number, ON-999-ENTER causes
the camera to enter the FastAddress mode, which is
required to change or disable a FastAddress.
ON-998-ENTER causes all cameras, regardless of
FastAddress status, to enter the addressing mode.
3. Press ON-26-ENTER to display the screen shown
in FIGURE 3. At this point, any camera whose ID
does not begin with 26 will exit the FastAddress
mode.
Figure 3: Fast Address, continued
Bosch Security Systems | 10 December 2003
4. Press ON-636-ENTER to display the screen shown
in FIGURE 4. At this point, Camera ID 26636 will
be the only camera in the FastAddress mode.
Figure 4: Fast Address, continued
5. Press ON-1-ENTER and the address is set. The
FastAddress is stored to nonvolatile memory and will
not change if power is removed or factory defaults
are restored (SET-899-ENTER).
To check/confirm the address, call up the camera and
press ON-997-ENTER. This command causes all
cameras to briefly display their addresses.
Incompatibility Statement:
The BasicDomes use the remote addressing
feature, FastAddress, exclusively. There is no
manual way to set the address using switches.
Hence, these domes are not compatible with
Bosch systems that meet the following criteria:
• Fixed Speed Keyboards.
• LTC 8500 / LTC 8600 / LTC 8800 CPUs
having version 5.2 or older.
• Any LTC 8500 / LTC 8600 / LTC 8800
CPUs without two 8-position dip switches.
• Any LTC 8600 / LTC 8800 sold before
6/94 and LTC 8500 sold before 5/95.
Older LTC 8500 / LTC 8600 / LTC 8800
systems can be upgraded by replacing the
CPU with the current version. Changes to
other system accessories may also be
necessary when upgrading to variable speed
(i.e., keyboards, receiver/drivers, port
expanders, etc.).