en | Getting Started
NOTICE!
Some Pelco controllers do not support all of the preset command numbers. Consult the
documentation of the specific Pelco controller for supported preset commands.
6.4

Setting the Camera Address via FastAddress

The MIC550 Classic offers remote addressing via the feature "FastAddress," which allows you
to set or to change a camera address using the keyboard and on-screen menus. The feature
FastAddress allows you to install all cameras first, then to set the addresses via the control
system. Since it is not necessary to go to the physical location of the camera, this feature
makes it easier to re-address cameras at a later time.
NOTICE!
You do not need to set a camera address if using Bilinx communication.
FastAddress is stored in nonvolatile memory and does not change if the power is turned off or
if the default settings are restored.
6.4.1

FastAddress, Bosch Protocol

In Bosch protocol, there are three (3) FastAddress commands:
NOTICE!
If a keyboard is set to a camera number that already has an address, that camera also
responds to this command.
To set an address for a camera without an address:
1.
2.
3.
4.
To change or clear an address for a camera with an address:
1.
2.
3.
4.
6.4.2

FastAddress, Pelco Protocols

This section provides instructions to set a FastAddress with a Pelco keyboard or controller.
F.01U.276.622 | 1.0 | 2012.09
ON-999-ENTER: Displays and programs all cameras without an address in the system.
ON-998-ENTER: Displays and programs all cameras with or without an address in the
system.
ON-997-ENTER: Displays the current address status of all cameras in the system
simultaneously.
Select the number of the camera that you want to FastAddress. The system displays the
camera number on the keyboard and the image on the corresponding monitor.
Press #-ENTER (where # is the camera number without an address).
Press ON-999-ENTER to invoke an on-screen display of cameras on the system without
an address.
Follow the on-screen instructions. You receive an on-screen confirmation when the
FastAddress is complete.
Select the camera number you want to FastAddress. The system displays the camera
number on the keyboard and the image on the corresponding monitor.
Press #-ENTER (where # is the camera number with an address).
Press ON-998-ENTER to invoke an on-screen display of all cameras on the system, with or
without an address.
Follow the on screen instructions. You receive an on-screen confirmation when the
FastAddress is complete.
A MIC550 camera with an address set to 0 responds to commands set to any address.
Pelco-P protocol must use addresses 1 to 32.
Installation and User Manual
MIC Series 550 Classic Camera
Bosch Security Systems, Inc.