Indoor Pendant & In-ceiling Models | Instruction Manual | Installation
2.2 Wire the Connector (Pendant
Housings)
Wire the connector as shown below.
CONTROL CONNECTOR
9 8 7 6 5 4 3 2 1
C-
C+ GND RXD TXD GND
Biphase
Ground
Biphase +
Biphase -
Figure 1: Control Connector
If a prewired mount was purchased, this step has been
done for you at the factory. Attach wires to the empty
pendant housing.
For added protection from EMI or RFI interference,
the ferrite provided must be snapped around the
power cable as close to the control connector as
possible (see PHOTO 3 inset).
Photo 3: Snap Ferrite into Place
2.3 Attach Pendant to Housing
(Pendant Housings)
While holding the empty pendant housing in one
hand, screw the pendant to the mount using the two
Phillips head screws permanently mounted inside the
pendant housing (see PHOTO 4).
Bosch Security Systems | 10 December 2003
H
24 VAC
Retaining
Screw
RS-232
Ground
24 VAC Line
RS-232 TX
24 VAC Neutral
RS-232 RX
Not Used
Photo 4: Attach Pendant to Housing
NOTE: SECTION 2.4 refers to both BackBox
and Pendant Housing installations.
2.4
Insert the Camera Module into the
Housing
1. While holding the top portion of the camera, rotate
the lower portion and align the yellow dots on the
side of the unit.
Photo 5: Align Yellow Dots
2. With the red dot on the camera module facing the
red dot in the backbox or pendant housing, slide
the camera module in. Note that the camera
module's shape will not allow you to insert it
incorrectly (see PHOTO 6). DO NOT FORCE!