Maintenance

Install Upgrade Token

1. Ensure system is inactive and control power is on.
2. Remove access cover (C).
F
. 7: Remove Access Cover
IG
3. Insert and press token (T) firmly into slot.
There is no preferred orientation of token.
L
S
F
. 8: Install Token
IG
10
C
ti12358a
M
ti12359a
T
4. Press and hold the left red token upload button (M)
for three seconds. The red indicator light (L) will
flash up to three seconds after the software is
uploaded.
5. Remove token (T).
6. Replace access cover (C).
7. Repeat procedure for all low power temperature
control modules.
8. Turn machine power off then on after all modules
are upgraded.

Clean

Keep heat sink fins clean at all times. Wipe the fins
clean with a dry cloth or clean them using compressed
air.