Graco Trabon LC-1000 User Manual

Graco Trabon LC-1000 User Manual

Lube system controller

Advertisement

LC-1000 Lube System Controller
The Trabon microprocessor based LC-1000 Controller
is a multi-use solid state controller that is dedicated to
the operation and monitoring of intermittent operat-
ing series and parallel centralized lubrication systems
equipped with a cycle or pressure switch for cycle
completion feed back.
The LC-1000 monitors and schedules lubrication inter-
vals in either time or stroke/cycle basis in values rang-
ing from 1 to 9999. Pump may be self cycling or single
cycle type requiring a pulsed output.
Four units are available for 12 VDC, 24 VDC, 115
VAC, or 230 VAC operation. The LC-1000 is easy to
program in the fi eld using four mini push-buttons. The
programming requires no special knowledge or training
of computer language. During power down or outage,
all data is saved in EEPROM (Electrically Erasable Pro-
gramming Read Only Memory). As power is restored,
counting and pump status are restored to values prior
to the loss of power.

SPECIFICATIONS

Power Supply
115 VAC + 10%, 50/60 Hz, 1 ph
230 VAC + 10%, 50/60 Hz, 1 ph
12 VDC + 10%
24 VDC + 10%
Output Loading
Main Pump Load: ..........12 VDC – 230 VAC, 50/60 Hz
10 Amp Relay Output (External Fused by User)
Fault Output Signal: ........12 VDC – 230 VAC, 50/60 Hz
1 Amp Resistive Max. (N.O.) Dry Isolated Contact
(External Fused by User)
Temperature Range
Do Not Locate unit in Direct Sunlight
Operating:: -20
O
C to 50
Storage: -25
C to 60
C (-13
O
O
Enclosure
Plastic with Clear Cover, NEMA 4X, IP 66
O
C (-4
O
F to 122
O
F)
F to 140
F)
O
O
Display
Supertwist LCD
Annotated 4 Digit
4 LED's: PWR (GN), LUBE (YW), FAULT (RD),
CYCLE (YW)
Stroke Input
Maximum Input Rate: 10 hz (600 CPM)
Nominal 12 Volts for 12 VDC Version
Nominal 24 Volts for 24 VDC, 115 VAC, 230 VAC
Versions
Selectable for either Source or Sink Solid State
Proximity Switch or Dry Contact 10 mA Max.
Other Inputs
Cycle Switch: ........12 Volts, Dry Contact, 2.5 mA Max.
Counts Half Cycles
Programming Selection
Output ON: ...................... 1 to 9999 Seconds, Minutes,
Output OFF:..................... 1 to 9999 Seconds, Minutes,
Cycle Counter: .............................Half Counts (0 to 99)
Pump: ....................................... Steady State or Pulsed
Pulse Off Time (Prime) – 3 Seconds Fixed
Pulse On Programmable - 0 to 99 Seconds
(Pre-Lube function is not available)
Program Entry
4 Mini Push Buttons – Program, Increase, Shift, Enter
EEPROM
Electrically Erasable Programming Read Only Memory
Hours, Counts
Hours, Counts

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Trabon LC-1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Graco Trabon LC-1000

  • Page 1: Specifications

    LC-1000 Lube System Controller The Trabon microprocessor based LC-1000 Controller is a multi-use solid state controller that is dedicated to the operation and monitoring of intermittent operat- ing series and parallel centralized lubrication systems equipped with a cycle or pressure switch for cycle completion feed back.
  • Page 2: Wiring Information

    LC-1000 Lube System Controller Option for units built after February 1, 1999 that are programmed in time mode. INPUT VOLTAGE FIG 1 INPUT OUTPUT CLOSURE OF SWITCH CONTACTS CAUSES LC-1000 TO INDICATE A FAULT CONDITION. BUT PUMP WILL CONTINUE TO OPERATE. All units programmed in machine count mode, or any units built prior to Februay 1, 1999.
  • Page 3: Ordering Information

    LC-1000 Lube System Controller DIMENSIONS mm / (Inches) TIME COUNTS REMAINING 127.0 (5.00) PRGM MODEL LC-1000 MANUAL RUN BUTTON ORDERING INFORMATION LC-1000 Controller VOLTAGE PART NUMBER 12 VDC 24 VDC 115 VAC, 50/60 Hz 230 VAC 50/60 Hz Replacement Board VOLTAGE PART NUMBER 12 VDC...
  • Page 4: Operation

    LC-1000 Lube System Controller OPERATION When power is applied, the green “POWER LED”lights and the LC-1000 counts down alternately from the programmed “OFF/ON” Times/Counts to zero. In the “ON” (Monitor) mode, the ” PUMP LED” lights. The pump is activated and both the “ON and “RUN” icons are displayed.
  • Page 5 LC-1000 Lube System Controller Sample LC-1000 Program for Series Progressive, 31 Point Series Progressive System DESCRIPTION ■ System Lube Volume: 6.0 cu in (99 cc) per hour ■ AL-50 Pump Used: .24 cu in per stroke (3.9 cc) ■ Master Divider Volume per Cycle: .15 cu in (2.4 ■...
  • Page 6 LC-1000 Lube System Controller Sample LC-1000 Program for Piston Distributor or Injector Systems 31 Point Piston Distributor System DESCRIPTION ■ System Lube Volume: 99 cc (6.0 cu in) per hour ■ EO-3 Motor Driven Pump: 140 cc/min (8.5 cu in) ■...
  • Page 7 LC-1000 Lube System Controller Sample LC-1000 Program for Bi-Flo (Dual Line) Systems 31 Point Bi-Flo (Dual Line) System DESCRIPTION ■ System Lube Volume: 6.0 cu in (99 cc) per hour ■ Bi-Flo Motor Driven Pump Used: 8.6 cu in (141 cc) per minute.
  • Page 8: Troubleshooting

    Fig. 1 All written and visual data contained in this document are based on the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice Call today for product information or to request a demonstration.

This manual is also suitable for:

Lc-1000

Table of Contents

Save PDF