Fault tracing
Preconditions
If preheating is activated the preheat symbol will be
visible in the tachometer and/or the display.
Fault condition 1
The engine does not crank when the start/preheat but-
ton is pushed.
Possible reason
The neutral switch is not activated (switch open).
The coolant temperature is below 50 °C (122 °F) and
therefore preheating is activated.
Open circuit between the MDI start output and the
starter solenoid at the starter motor.
Faulty starter solenoid at the starter motor.
Faulty starter relay inside the MDI unit (not replace-
able).
Suitable action
1 Check that the neutral switch is activated (switch
closed).
2 Preheating is activated due to too cold coolant tem-
perature. Repress the start/preheat button within 10
seconds to activate the starter motor.
3 Check wiring and the connections between the MDI
start output and the starter solenoid at the starter
motor.
4 Check the starter solenoid at the starter motor.
5 Try with another MDI unit.
Fault condition 2
The preheat symbol is not visible in the tachometer
and/or the display.
Possible reason
The coolant temperature is above 50 °C (122 °F)
and therefore preheating is not activated.
Open circuit between the MDI preheating output and
the glowing plugs.
Faulty preheat relay inside the MDI unit (not replace-
able).
Suitable action
1 Check the wiring and connections between the MDI
and the glowing plugs via the conductor rail.
2 Try with another MDI unit.
30-2 Fault Tracing