30-2 Fault Tracing
22
Measurements
Check speed sensor, flywheel
Tools:
88890074 Multimeter
9998699 Break-out box
88890016 Break-out cable
Check 1
1
NOTICE! Cut the current with the main switch.
2
Connect 88890016 Break-out cable with
9998699 Break-out box between MDI and engine
connector. Do not connect the MDI.
3
Use 88890074 Multimeter for resistance meas-
urement.
Measurement points
17 - 18
47704383 06-2013 © AB VOLVO PENTA
Nominal value
R ≈ 0,9 kΩ