18
17
P0008424
47704383 06-2013 © AB VOLVO PENTA
4
Remove the sensor from the flywheel casing.
Check that the sensor has no external damage
and that no metal chips are stuck on the sensor.
MDI
5
Use 88890074 Multimeter for a AC voltage meas-
urement.
6
Move a metal object rapidly back and forwards
not more than 1 mm (0.039") in front of the sen-
sor. Check that the multimeter gives a reading.
7
Install the sensor.
30-2 Fault Tracing