Volvo Penta D1-13 Workshop Manual page 21

Group 30
Hide thumbs Also See for D1-13:
Table of Contents

Advertisement

20
16
P0008414
47704383 06-2013 © AB VOLVO PENTA
Checking the coolant temperature sensor
Tools:
88890074 Multimeter
9998699 Break-out box
88890016 Break-out cable
1
NOTICE! Cut the current with the main switch.
2
Connect adapter cable 88890016 Break-out
cable with 9998699 Break-out box and with the
MDI
engine connector. Do not connect the MDI.
3
Use 88890074 Multimeter for resistance meas-
urement.
NOTICE! All resistance values shall be seen as guide
line values.
Measurement points
16 - 20
16 - 20
16 - 20
16 - 20
16 - 20
16 - 20
16 - 20
16 - 20
16 - 20
16 - 20
16 - 20
16 - 20
16 - 20
30-2 Fault Tracing
Nominal value
R ≈ 1743 Ω at 0°C
R ≈ 1076 Ω at 10°C
R ≈ 677 Ω at 20°C
R ≈ 439 Ω at 30°C
R ≈ 291 Ω at 40°C
R ≈ 197 Ω at 50°C
R ≈ 134 Ω at 60°C
R ≈ 97 Ω at 70°C
R ≈ 70 Ω at 80°C
R ≈ 51 Ω at 90°C
R ≈ 38 Ω at 100°C
R ≈ 29 Ω at 110°C
R ≈ 22 Ω at 120°C
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D1-20D1-30D2-40

Table of Contents