Helios GBW EC Series Installation And Operating Instructions Manual

Helios GBW EC Series Installation And Operating Instructions Manual

Gigabox centrifugal fans
Table of Contents

Advertisement

Available languages

Available languages

Helios Ventilatoren
MONTAGE- UND BETRIEBSVORSCHRIFT
INSTALLATION AND OPERATING INSTRUCTIONS
NOTICE DE MONTAGE ET D'UTILISATION
EC-Radialventilatoren
EC-Centrifugal fans
Caissons centrifuges EC
GigaBox
GBW EC ...
GBD EC ...
DE
EN
FR

Advertisement

Table of Contents
loading

Summary of Contents for Helios GBW EC Series

  • Page 1 Helios Ventilatoren MONTAGE- UND BETRIEBSVORSCHRIFT INSTALLATION AND OPERATING INSTRUCTIONS NOTICE DE MONTAGE ET D’UTILISATION EC-Radialventilatoren EC-Centrifugal fans Caissons centrifuges EC GigaBox GBW EC ... GBD EC ...
  • Page 2: Table Of Contents

    DEUTSCH Inhaltsverzeichnis KAPITEL 1 ALLGEMEINE MONTAGE- UND BETRIEBSHINWEISE ........Seite 1 Wichtige Informationen .
  • Page 3: Wichtige Informationen

    Wenn die nachfolgenden Ausführungen nicht beachtet werden, entfällt unsere Gewährleistung. Gleiches gilt für Haf- tungsansprüche an den Hersteller. Der Gebrauch von Zubehörteilen, die nicht von Helios empfohlen oder angeboten werden, ist nicht statthaft. Even tuell auftretende Schäden unterliegen nicht der Gewährleistung.
  • Page 4: Laufräder

    Montage- und Betriebsvorschrift Radialventilatoren – GigaBox GBW EC.. / GBD EC.. – Elektrische Werte Das Typenschild gibt über die elektrischen Werte Auf schluss. Diese sind auf Übereinstimmung mit den örtlichen Gege- benheiten zu überprüfen. – Akustik Das GigaBox-Gehäuse ist schallisoliert. Gehäuse vibra tionen, ungünstige Betriebsbedingungen u.a. können zu einer Erhöhung der angegebenen Werte führen.
  • Page 5: Motorschutzeinrichtung

    Abb.3 Der Einsatz von Fremdfabrikaten kann, v.a. bei elektronischen Geräten, zu Funktionsproblemen, Zerstörung WARNUNG des Reglers und/-oder des Ventilators führen. Bei Einsatz seitens Helios nicht freigegebener Regel- und Steuergeräte entfallen Garantie und Haftungsansprüche! Steuerung mehrerer EC-Ventilatoren mit einem Potentiometer Zur Ansteuerung mehrerer EC-Ventilatoren über den Sollwerteingang “0-10 V“, muss die 10 V DC -Spannungs- quelle die Summe aller Sollwerteingänge-Bürdenströme zu Verfügung stellen.
  • Page 6: Lieferumfang

    Die Zubehörtteile sind in unterschiedlichen Größen und Kondensatwanne mit Ablaufstutzen für Ausführungen erhältlich. Die entsprechende Bestell.-Nr. Rohr-/Schlauch-An- kann den Helios Verkaufsunterlagen entnommen werden. schluss Die zu den EC-Baureihen zugehörigen Drehzahl-Po- tentiometer und das Universal-Regelsystem EUR EC können aus dem aktuellen EC-Katalog „EC greenVent –...
  • Page 7: Abmessungen Anschlussflansch (Austritts-Formstück)

    Funktionsbeschreibung Die GigaBox GB EC.. Ventilatoren sind mittels 0-10 V Steuerspannung stufenlos drehzahlsteuerbar. Geeignete Potentiometer (Type PU/A 10), Dreistufen-Schalter (Type SU/A) werden im Helios Zubehörprogramm angeboten. Stufenlose Drehzahlregelung ist mit Universal-Regelsystem (Type EUR EC) möglich. Alternativ kann der elektronische Differenzdruck-/Temperatur-Regler EDR / ETR eingesetzt werden.
  • Page 8: Montage

    Montage- und Betriebsvorschrift Radialventilatoren – GigaBox GBW EC.. / GBD EC.. Abb.9 Kondensatablauf über Kondansatwanne GB-RA (Zubehör) an der Geräteun- terseite – Kondensatbildung WICHTIGE HINWEISE Kondensatbildung im Gerät wird durch doppelwandige wärmegedämmte Paneelen nahezu ausgeschlossen. Mit Kon- densatbildung muss jedoch bei sehr feuchten bzw. dampfhaltiger Luft gerechnet werden. Kondensat bildet sich vor allem in nicht isolierten Rohrleitungen, welches dann auch in den Ventilator laufen kann.
  • Page 9: Reinigung Und Wartung

    Montage- und Betriebsvorschrift Radialventilatoren – GigaBox GBW EC.. / GBD EC.. HINWEIS Berührungsschutz - Montagerückstände und Fremdkörper aus Ventilatorraum entfernt. - Ventilatorlaufrad darf nicht an feststehenden Gehäuseteilen schleifen - Kabeleinführung dicht. - Stimmen Anschlussdaten mit Daten auf Ventilatortypenschild überein – Inbetriebnahme: - Motor durch schalten des Freigabesignals in Betrieb nehmen.
  • Page 10: Standard Anschlusspläne

    Montage- und Betriebsvorschrift Radialventilatoren – GigaBox GBW EC.. / GBD EC.. Standard Anschlusspläne SS-973 GBW EC 250 GBW EC 315 GBW EC 355 GBW EC 400 A GBW EC 400 B GBW EC 450 Wechselstrom, 1~, 230 V SS-976 GBD EC 450/500 A/B/560/630/710 A/B Drehstrom, 3~, 400 V...
  • Page 11: Anschlusspläne Mit Pu/A Und Eur Ec

    Montage- und Betriebsvorschrift Radialventilatoren – GigaBox GBW EC.. / GBD EC.. Anschlusspläne mit PU/A und EUR EC SS-974 SS-975...
  • Page 12 Montage- und Betriebsvorschrift Radialventilatoren – GigaBox GBW EC.. / GBD EC.. SS-977 SS-978...
  • Page 13 Montage- und Betriebsvorschrift Radialventilatoren – GigaBox GBW EC.. / GBD EC.. SS-1035...
  • Page 14 ENGLISH Table of Contents CHAPTER 1. GENERAL INFORMATION ............Page 1 Important information .
  • Page 15: Important Information

    If the preceding instructions are not observed all warranty claims and accommodation treatment are excluded. This also applies to any liability claims extended to the manufacturer. The use of accessories not offered or recommended by Helios is not permitted. Potential damages are not liable for warranty.
  • Page 16: Impellers

    Installation and Operating Instructions Centrifugal fans – GigaBox GBW EC.. / GBD EC.. - Electrical parameters The motor rating plate provides information on the electrical data. These data are to be examined for its conformity to the local conditions. - Acoustics The Gigabox casing is acoustically insulated.
  • Page 17: Motor Protection

    The use of other brands, especially other electronic devices, can lead to malfunctioning and even destruc- WARNING tion of controller and/or fan. Controllers which have not been cleared by Helios are not liable for warranty and guarantee claims. Control of several EC-fans with a potentiometer In order to control several EC-fans via the setpoint input “0-10V”, the 10VDC -voltage source must provide the...
  • Page 18: Chapter 2. Scope Of Delivery And Accessories

    The accessories are available in different sizes and Condensate collector designs. The corresponding Ref. no. can be found in the with outlet spigots for Helios sales documentation. duct/hose connecti- The associated speed-potentiometers and the universal control system EUR EC are shown in the current EC-catalogue “EC greenVent - Ventilation in...
  • Page 19: Dimensions Connecting Flange (Outlet Adapter)

    The GigaBox GB EC.. fans are steplessly speed-controllable by means of 0-10 V control voltage. Suitable potentiometers (Type PU/A 10), three-step switches (Type SU/A) are offered in the Helios accessories range. Stepless speed control is possible with the universal controller (Type EUR EC). Alternatively, the electronic differential pressure/temperature controller EDR / ETR can be used.
  • Page 20: Installation

    Installation and Operating Instructions Centrifugal fans – GigaBox GBW EC.. / GBD EC.. Fig.9 Condensate collector GB-RA (accessories) for condensate drainage at the bottom of the unit – Condensate formation IMPORTANT NOTE Condensate formation in the unit is almost impossible due to the double-walled thermally insulated panels. Never- theless, condensate formation can be expected in case of very humid media or moisture-containing air.
  • Page 21: Cleaning And Maintenance

    Centrifugal fans – GigaBox GBW EC.. / GBD EC.. – Protection against accidental contact NOTE - Remove assembly residuals and foreign parts from the ventilation room. - Test unhindered running of the impeller. - Check if cable gland is tight. - Do the connection data agree with the data on fan rating plate –...
  • Page 22: Standard Wiring Diagrams

    Installation and Operating Instructions Centrifugal fans – GigaBox GBW EC.. / GBD EC.. Standard wiring diagram SS-973 GBW EC 250 GBW EC 315 GBW EC 355 GBW EC 400 A GBW EC 400 B GBW EC 450 Alternating current, 1~, 230 V Terminal box SS-976 GBD EC 450/500 A/B/560/630/710 A/B rotary current, 3~, 400 V...
  • Page 23: Wiring Diagrams With Pu/A And Eur Ec

    Installation and Operating Instructions Centrifugal fans – GigaBox GBW EC.. / GBD EC.. Wiring diagram with PU/A and EUR EC SS-974 Terminal box SS-975 Example: EUR EC control EC-Motor SS-973, with modus 4.01 (pressure controlled)
  • Page 24 Installation and Operating Instructions Centrifugal fans – GigaBox GBW EC.. / GBD EC.. SS-977 SS-978 Example: EUR EC control EC-Motor SS-976, with modus 4.01 (pressure controlled)
  • Page 25 Installation and Operating Instructions Centrifugal fans – GigaBox GBW EC.. / GBD EC.. SS-1035...
  • Page 26 FRAN ÇAIS Sommaire CHAPITRE 1 INFORMATIONS GÉNÉRALES CONCERNANT LE MONTAGE ET L’UTILISATION ... . Page 1 Informations importantes ..............Page 1 Précautions et consignes de sécurité...
  • Page 27: Informations Importantes

    En cas de non-respect des indications suivantes, toute demande de remplacement ou de réparation à titre gratuit sera déclinée. Il en sera de même pour toute implication du fabricant. L’utilisation d’accessoires et d’équipements qui ne sont directement fournis ou conseillés par Helios n’est pas permise. Nous déclinons toute responsabilité en cas de défaut consécutif à leur utilisation.
  • Page 28: Turbines

    Notice de montage et d’utilisation Caissons centrifuges – GigaBox GBW EC.. / GBD EC.. – Valeurs électriques Les valeurs électriques sont indiquées sur l’étiquette. Elles sont à vérifier en fonction des réglementations spécifiques locales. – Acoustique Le caisson du GigaBox possède une isolation phonique. Les vibrations du caisson, ainsi que des conditions de foncti- onnement défavorables, entre autres, peuvent conduire à...
  • Page 29: Protection Moteur

    Si la puissance utile de la tension de commande n’est pas suffisante, il est possible d’utiliser une alimentation externe 10 V DC (avec séparation galvanique du réseau). Pour une régulation par sondes de température, pression, vitesse, etc., utiliser le régulateur universel Helios EUR EC. 1.17 Protection moteur Tous les modèles GigaBox EC sont équipés de moteurs à...
  • Page 30: Contenu De La Livraison

    Le choix des accessoires se fait en fonction de la taille et de la version. Le n° de référence correspondant se Bac de récupération des trouve dans les documentations commerciales Helios. condensats avec raccord d’écoulement Les potentiomètres de vitesse de rotation et les pour tuyau/tube régulateurs universels EUR EC correspondant aux...
  • Page 31: Dimensions Des Pièces De Raccordement

    GBW EC 500-710 Description des fonctionnalités Les ventilateurs GigaBox GB EC.. se régulent via potentiomètre 0-10 V. Helios propose les potentiomètres (type PU/A 10) et les interrupteurs à trois étages (type SU/A) adéquats. Régulation possible avec le régulateur universel (type EUR EC).
  • Page 32: Montage

    Notice de montage et d’utilisation Caissons centrifuges – GigaBox GBW EC.. / GBD EC.. Fig.9 Évacuation des condensats au cendre du bac GB-RA (accessoire) sous l’appareil - Formation de condensats IMPORTANT La formation de condensats dans l’appareil est quasiment exclue du fait des panneaux double peau isolés thermique- ment.
  • Page 33: Nettoyage Et Entretien

    Notice de montage et d’utilisation Caissons centrifuges – GigaBox GBW EC.. / GBD EC.. Protection contre les contacts CONSEILS − Retirer les résidus du montage et les corps étrangers du caisson du ventilateur. − S’assurer que la turbine du ventilateur ne frotte pas contre les pièces fixes du caisson. −...
  • Page 34: Schémas De Branchement Standard

    Notice de montage et d’utilisation Caissons centrifuges – GigaBox GBW EC.. / GBD EC.. Schémas de branchement standard SS-973 GBW EC 250 Moteur EC GBW EC 315 GBW EC 355 Valable à partir des versions GBW EC 400 A ouvert quand déclenchement 5810 002 et 5811 002.
  • Page 35 Notice de montage et d’utilisation Caissons centrifuges – GigaBox GBW EC.. / GBD EC.. Schémas avec PU/A et EUR EC SS-974 Code couleur selon CEI 757 BK - noir Boîte à bornes Moteur EC BN - marron RD - rouge OG - orange YE - jaune GN - vert...
  • Page 36 Notice de montage et d’utilisation Caissons centrifuges – GigaBox GBW EC.. / GBD EC.. SS-977 Moteur EC ouvert lorsque déclenché Valeur de consigne Alimentation 1 Potentiomètre Vitesse min. Alimentation 2 Déverrouillage ON/OFF Report original Fonctionnement affichage LED Borne 6 Borne 7 rouge vert Affichage LED...
  • Page 37 Notice de montage et d’utilisation Caissons centrifuges – GigaBox GBW EC.. / GBD EC.. SS-1035...
  • Page 40 HELIOS Ventilatoren GmbH + Co KG · Lupfenstraße 8 · 78056 VS-Schwenningen HELIOS Ventilateurs · Le Carré des Aviateurs · 157 avenue Charles Floquet · 93155 Le Blanc Mesnil Cedex CH HELIOS Ventilatoren AG · Tannstraße 4 · 8112 Otelfingen GB HELIOS Ventilation Systems Ltd.

Table of Contents