RCF BM 3023 User Manual
RCF BM 3023 User Manual

RCF BM 3023 User Manual

Dxt 9000 desk-top paging microphone

Advertisement

Available languages

Available languages

Quick Links

BM 3023
USER MANUAL
MANUALE D'USO
DXT 9000 DESK-TOP
PAGING MICROPHONE
BASE MICROFONICA
DA TAVOLO PER
SISTEMA DXT 9000

Advertisement

Table of Contents
loading

Summary of Contents for RCF BM 3023

  • Page 1 USER MANUAL MANUALE D’USO BM 3023 DXT 9000 DESK-TOP PAGING MICROPHONE BASE MICROFONICA DA TAVOLO PER SISTEMA DXT 9000...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INDICE ENGLISH SAFETY PRECAUTIONS DESCRIPTION FRONT PANEL REAR SIDE CONNECTION OPERATION PAGING INTERRUPTED BY OTHER DEVICES (in other lines) HAVING HIGHER PRIORITY PAGING WHEN THE SYSTEM IS BUSY DUE TO OTHER DEVICES SPECIFICATIONS ITALIANO AVVERTENZE PER LA SICUREZZA DESCRIZIONE PANNELLO FRONTALE RETRO...
  • Page 4: Safety Precautions

    RCF S.p.A. will not assume any responsibility for the incorrect installation and / or use of this product. SAFETY PRECAUTIONS 1.
  • Page 5: Description

    HAS BEEN DESIGNED TO GUARANTEE RELIABILITY AND HIGH PERFORMANCES. DESCRIPTION BM 3023 paging microphone is part of the BM 3222 console and needs to be matched to the CB 3002 COMMUNICATION BOX (to which it is linked by a CAT5 cable).
  • Page 6: Rear Side

    REAR SIDE Power Supply Input 24 V 150 mA 18 V 200 mA CALL RJ 45 output TO CB 3002 Power supply input for the necessary external adapter (included). Operating voltage: either 24 V dc (current draw: 150 mA) or 18 V ac (200 mA). RJ 45 output to link the CB 3002 COMMUNICATION BOX (cable: CAT5).
  • Page 7: Connection

    CONNECTION Link the paging microphone ‘RJ 45 Output to CB 3002’ output to the ‘BM 3023’ input of the CB 3002 COMMUNICATION BOX, by using a CAT5 cable with RJ 45 connectors. COMMUNICATION BOX GENERAL CALL TWIN / LOCAL CALL...
  • Page 8: Operation

    OPERATION TURNING THE SYSTEM ON (after connecting) After powering (through the included adapter) and linking the paging micro- phone to the DXT 9000 network, verify that (with no paging in progress) the ON / BUSY LED is indicating green. NO PAGING IN PROGRESS ON / BUSY LED : green This indication confirms that the paging microphone is properly powered and...
  • Page 9: Paging Interrupted By Other Devices (In Other Lines) Having Higher Priority

    (or keep pressed the handheld microphone push-button) and wait for the confirmation. It is possible to page only if the BM 3023 has a higher priority level then the other device that is engaging the system. If so, the microphone is immediately turned on. If not, the request is denied...
  • Page 10: Specifications

    SPECIFICATIONS Type: desk-top with handheld dynamic microphone Polar pattern: omnidirectional Output impedance: 500 Ω ± 30% (1 kHz) Microphone sensitivity: – 70 dB ± 3 dB (0 dB = 1V/μbar @ 1 kHz ) Frequency response: 300 Hz ÷ 6 kHz (– 3 dB) Power supply: 24 V dc (current draw: 150 mA) or 18 V ac (200 mA)
  • Page 12: Avvertenze Per La Sicurezza

    L’installazione e l’utilizzo errati del prodotto esimono RCF S.p.A. da ogni responsabilità. AVVERTENZE PER LA SICUREZZA 1. Tutte le avvertenze, in particolare quelle relative alla sicurezza, devono essere lette con particolare attenzione, in quanto contengono importanti informazioni.
  • Page 13: Descrizione

    REALIZZATO IN MODO DA GARANTIRNE L’AFFIDABILITÀ E PRESTAZIONI ELEVATE. DESCRIZIONE La base microfonica da tavolo BM 3023 è parte della console BM 3222 e si utilizza solo abbinata alla COMMUNICATION BOX CB 3002 (alla quale è collegata tramite cavo CAT5).
  • Page 14: Retro

    RETRO Power Supply Input 24 V 150 mA 18 V 200 mA CALL RJ 45 output TO CB 3002 Ingresso per il necessario alimentatore esterno (incluso). Tensione di funzionamento: 24 V c.c. (corrente assorbita: 150 mA) oppure 18 V c.a. (200 mA). Uscita con connettore RJ 45 per il cavo (di tipo CAT5) per il collegamento alla COMMUNICATION BOX CB 3002.
  • Page 15: Collegamento

    COLLEGAMENTO Collegare l’uscita “RJ 45 Output to CB 3002” della base microfonica all’ingresso “BM 3023” della COMMUNICATION BOX CB 3002, tramite un cavo CAT5 con connettori RJ 45. COMMUNICATION BOX GENERAL CALL TWIN / LOCAL CALL AUDIOC GENERAL CALL TWIN / LOCAL CALL...
  • Page 16: Funzionamento

    FUNZIONAMENTO ACCENSIONE DEL SISTEMA (dopo il collegamento) Dopo aver alimentato (tramite l’alimentatore incluso) e collegato la base microfonica alla rete del sistema DXT 9000, verificare che (in assenza di qualunque diffusione) il LED di stato sia acceso e verde. NESSUNA DIFFUSIONE LED “ON / BUSY”...
  • Page 17: Annunci Interrotti Da Altri Dispositivi (Su Linee Diverse) Aventi Maggiore Priorità

    (su linee diverse) AVENTI MAGGIORE PRIORITÀ I dispositivi aventi priorità superiore possono interrompere un annuncio in corso (od impedirlo) da una base microfonica BM 3023; tale evento è segnalato dal cambiamento dello stato degli indicatori luminosi (LED): LED ON / BUSY Sistema occupato: non è...
  • Page 18: Dati Tecnici

    DATI TECNICI Tipo: base da tavolo con microfono palmare dinamico Direttività: omnidirezionale Impedenza d’uscita: 500 Ω ± 30% (1 kHz) Sensibilità microfono: – 70 dB ± 3 dB (0 dB = 1V/μbar @ 1 kHz ) Risposta in frequenza: 300 Hz ÷ 6 kHz (– 3 dB) Alimentazione: 24 V corrente continua (assorbimento 150 mA) oppure 18 V corrente alternata (assorbimento 200 mA)
  • Page 20 Salvo eventuali errori ed omissioni. RCF S.p.A. si riserva il diritto di apportare modifiche senza preavviso. Except possible errors and omissions. RCF S.p.A. reserves the right to make modifications without prior notice. www.rcf.it RCF S.p.A. Italy Via Raffaello Sanzio, 13...
  • Page 21 OWNER MANUAL CB 3002 COMMUNICATION BOX...
  • Page 22 LANGUAGE ENGLISH ITALIANO...
  • Page 23 CB 3002 shall be installed between the BM 3023 console and DXT 9000 amplifiers unit, and it is equipped with all the electronics necessary to execute BM 3023 types of calls, namely: - General call (GENERAL) covering the entire gates line;...
  • Page 24 INSTALLATION CB 3002 has a metal case having a size of ½U rack width and 1U height, and thanks to removable ears can be installed both in ceiling (or false ceiling) and wall mount configuration, corners included. Be sure to use proper mounting elements depending on the specific surface. CEILING MOUNTING CORNER...
  • Page 25 All connectors are placed on the rear panel, for easier cabling in any configuration. On the front panel status and power supply LEDs are placed. GENERAL CALL, TWIN CALL e LOCAL CALL LEDs indicate which type of call is activated on BM 3023. The POWER SUPPLY indicates device correct power supply.
  • Page 26 CONNECTIONS IN THE SYSTEM It is possible to connect up to 62 CB 3002 to a DXT 9000 system, 2 for each Amplifier Unit. The following figure shows an example of a system that uses the BM 3222 solution for airport gates line.
  • Page 27 IN THE SYSTEM CONNECTION BETWEEN BM 3023 AND CB 3002 To connect the desktop microphone console BM 3023 and CB 3002 use a CAT5 (or higher) cable, as shown in figure. CONNECTION OF THE CB 3002 CHAIN (GENERAL CALL BUS)
  • Page 28 CONNECTIONS IN THE SYSTEM CONNECTION OF CB 3002 AND UP 950X (LOCAL /TWIN CALL BUS) It is possible to connect up to 2 CB GPIs that can be used are both the ones on 3002 to each UP 950x as shown in the Master Unit or on UP950x connected to the figure, one to BGM3 and one to the CB 3002.
  • Page 29 CB 3002 è un dispositivo che si installa tra le console BM 3023 e le unità slave di un sistema DXT 9000, ed è equipaggiato con tutta l’elettronica necessaria all’esecuzione delle tipologie di chiamate della BM 3023, vale a dire: - chiamata generale (GENERAL) che si diffonde a tutta la catena di gate;...
  • Page 30 INSTALLAZIONE CB 3002 ha un case metallico di dimensioni pari a ½U rack in larghezza ed 1U rack in altezza, e grazie alle alette removibili può essere installato a muro o su qualunque altra superficie piana, oltre che a rack, accoppiando due scatole in un’unica unità. INSTALLAZIONE A SOFFITTO INSTALLAZIONE...
  • Page 31 Master Unit del sistema. Trasportano sia audio che comandi. Connettore a 4 poli di collegamento alle unità slave del sistema. Trasporta sia audio che comandi. Connettore RJ45 per collegare la console BM 3023. Utilizzare un cavo CAT5 (o superiori). Connettore per alimentatore AC AD2405.
  • Page 32 CONNESSIONI ALL’INTERNO DEL SISTEMA È possibile collegare complessivamente ad un sistema fino a 62 CB 3002, 2 per ciascuna unità slave del sistema DXT 9000. La figura che segue mostra un esempio di un sistema che utilizza la soluzione BM 3222 per la sonorizzazione di gate aeroportuali.
  • Page 33 CONNESSIONI ALL’INTERNO DEL SISTEMA CONNECTION BETWEEN BM 3023 AND CB 3002 Per collegare la console microfonica BM 3023 e la CB 3002 basta utilizzare un cavo CAT5 (o superiori) tra i connettori come mostrato in figura. COLLEGAMENTO DELLA CATENA CB 3002...
  • Page 34 CONNESSIONI ALL’INTERNO DEL SISTEMA COLLEGAMENTO FRA CB 3002 E UP 950X LOCAL /TWIN CALL BUS) Si possono collegare 2 CB 3002 I GPI che si possono utilizzare sono per ogni UP 950x e devono essere indistintamente quelli dell’unità master o collegati come mostrato in figura, dell’UP950x a cui si collega la CB 3002.
  • Page 36 RCF S.p.A. Via Raffaello Sanzio, 13 42124 Reggio Emilia - Italy Tel +39 0522 274 411 Fax +39 0522 232 428 e-mail: info@rcf.it...
  • Page 37 USER MANUAL MANUALE D’USO AC AD2405 AC AD2405 AC/DC ADAPTER ALIMENTATORE AC AD2405...
  • Page 39 RCF S.p.A. will not assume any responsibility for the incorrect installation and / or use of this product.
  • Page 40 RCF products that (always or in particular circumstances) need 24 V dc power supply. For instance, it can be used as power supply unit for the RCF BM 3003 paging microphone. This adapter can be connected to mains through continental European sockets only.
  • Page 41 (ed anche il tipo: continua o alternata) siano compatibili con quelli di targa del prodotto da alimentare, in caso contrario rivolgersi ad un rivenditore RCF. Verificare inoltre che l’alimentatore non sia stato danneggiato da eventuali urti o sovraccarichi.
  • Page 42 PRESTAZIONI ELEVATE. DESCRIZIONE L'alimentatore AC AD2405 può essere collegato (compatibilmente con la sua corrente massima erogabile) a tutti quei prodotti RCF che necessitano, sempre od in particolari circostanze, dell'alimentazione 24 V in corrente continua. Ad esempio: può essere utilizzato per alimentare la base microfonica RCF BM 3003.
  • Page 44 RCF SpA: Via Raffaello, 13 - 42124 Reggio Emilia > Italy tel. +39 0522 274411 - fax +39 0522 274484 - e-mail: rcfservice@rcf.it...

Table of Contents