Download Print this page
ICP DAS USA M2M-711D Faq
Hide thumbs Also See for M2M-711D:

Advertisement

Quick Links

TM
M2M-711D
FAQ
Version 1.00

Advertisement

loading
Need help?

Need help?

Do you have a question about the M2M-711D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ICP DAS USA M2M-711D

  • Page 1 M2M-711D Version 1.00...
  • Page 2: Table Of Contents

    Table of Contents Q01: If I forget the M2M-711D’s Ethernet IP, how can I set and operate the M2M-711D by web browser? ..................3 Q02: Client cannot connect to Server...............5 Q03: Server and Client can’t establish Com Port connection......8...
  • Page 3: M2M-711D By Web Browser

    Q01: If I forget the M2M-711D’s Ethernet IP, how can I set and operate the M2M-711D by web browser? A01: (1) :Please reset system. (2) : In Ethernet mode, the Ethernet IP address will show again. Display Ethernet IP address in Ethernet mode...
  • Page 4 (3) : In Wi-Fi/Ad Hoc mode, the Ethernet IP address will show again. (4):Init M2M-711D reference 2.3. Default value of Ethernet IP address is 192.168.1.217...
  • Page 5: Q02: Client Cannot Connect To Server

    Q02: Client cannot connect to Server. A02: Please follow the following steps to check that the network configuration is correct. Step 1: Check IP of Server and Client is the only. The IP is not the same with the other network device. Step 2: Please confirm the network configurations are correct.
  • Page 6 Check IP Config in Wi-Fi mode Step 3: Please confirm that the following settings are correct.  “Server IP” of Client is the same with “IP Address” of Server.  “Listen Port” of Server and “Communication Port” Client are the same. ...
  • Page 7 Client’s “Standard Config” page Server’s “Standard Config” page...
  • Page 8: Q03: Server And Client Can't Establish Com Port Connection

    Q03: Server and Client can’t establish Com Port connection. A3: Please follow the steps to check below. Step 1: Confirm client’s name is the same as server permission name list. Step 2: Confirm comport setting of server and client. Server comport setting must the same setting as client.
  • Page 9: Q04: Can The M2M-711D Operate In Both Ad-Hoc And Infrastructure Modes Simultaneously

    Comport setting of client Step 3: Does the inspection wiring have the question? Q04: Can the M2M-711D operate in both Ad-Hoc and Infrastructure modes simultaneously? A04: M2M-711D can't operate in both AP and Ad-Hoc modes simultaneously.
  • Page 10: Q05: What To Do If M2M-711D Does Not Work In Ap Mode

    Other PC(IP=192.168.200.200) <==> Wi-Fi AP(company wireless net) <==> VxServer in PC (IP=192.168.100.100) Step 2: M2M-711D replaces other PC. The network setting of M2M-711D must be same the network setting of other PC. ( Note: Server IP must be "192.168.100.100" in “standard config” page of M2M-711D.)
  • Page 11: Q06: How To Configure M2M-711D In Ad-Hoc Mode And Connect It By A Pc

    Q06: How to configure M2M-711D in Ad-Hoc mode and connect it by a PC? A06: Step1: Set Ad Hoc mode in M2M-711D. About Ad Hoc mode setting, please refer to the manual page 36th "3.3.4 Wireless Config". We suppose the Server IP= 192.168.100.100, SSID=ICPDAS, Wi-Fi IP= 192.168.200.200, and Wi-Fi Mask=255.255.0.0.
  • Page 12 Step3: Set network setting of PC. The IP must be "192.168.100.100", the netmask must be "255.255.0.0". Step4: Open VxServer and modify local IP="192.168.100.100". If it does without any M2M-711D on line, please close the firewall of windows. If these steps does not fix the problem, please contact us.