LOGO REPLACEMENT MODULE for FAM-5 Installation Manual English (translation of original instructions) Keep for future reference. Documentation no.: 4359963...
Content Content Content ......................2 Preceding note ....................2 Replacing the Logo! of the TDE module ............. 3 Preparing the Logo! of the TDE module ............4 Preparing the Logo! of the TDE module for assembly ......... 6 Installing the Logo! of the TDE module ............7 Determining the configuration of the FAM ..........
Replacing the Logo! of the TDE module Replacing the Logo! of the TDE module In this chapter, you will find the required specifications to replace the defective Logo! of the TDE module with a new module. The listed illustrations show the module at the front of the switch cabinet. It is at the head in the case of the FAM.
Replacing the Logo! of the TDE module NOTICE Unit in a condensation state Risk of a short circuit ► Do not switch on the Logo! of the TDE module when it is in a condensation state. ► Allow it to come to room temperature before commissioning it. ►...
Page 5
Replacing the Logo! of the TDE module 2. Pull the E-Box's power plug. 3. Open the door to the E-Box with the suitable key. 4. Disconnect all cables and connection plugs on the rear side of the Logo! of the TDE module. Unscrew the set screws out of the holding brackets counterclockwise.
Replacing the Logo! of the TDE module Preparing the Logo! of the TDE module for assembly Check the module for transport damage. The module may only be installed and operated in perfect technical condition, in compliance with this document. If no sealing cord has been glued in place in groove (A) on the rear side of the module's front panel, insert the sealing cord provided in groove (A) and cut the sealing cord to length so that the joint closes with a tight seal.
Replacing the Logo! of the TDE module Installing the Logo! of the TDE module In order to install the Logo! of the TDE module, proceed as follows: Prepare the Logo! of the TDE module for installation according to Chapter "Preparing the Logo! of the TDE module for assembly", page 6.
Page 8
Replacing the Logo! of the TDE module Only the Logo! of the TDE module with the four mounted holding brackets fulfil protection class IP65. Insert all cables and connection plugs into the corresponding ports on the rear side of the Logo! of the TDE module.
Page 9
Replacing the Logo! of the TDE module of the TDE module at starting. The user interface starts automatically. The assembly of the Logo! of the TDE module is complete. FAM 5 Page 9 / 12 en-US MOWA LogoTDE 4359963 en 2018-05-23.docx 2018-05-08...
Determining the configuration of the FAM Determining the configuration of the FAM In order to adapt the Logo! of the TDE replacement module to your FAM, you require the model version given in the model code. In order to decode this, use the following table.