Attenuation Repeatability; Rf Power Handling Capability; Solenoid Drive; Switching Speed - Keysight Technologies 8495D Operating And Service Manual

Table of Contents

Advertisement

Attenuation repeatability

±0.03 dB max to 18 GHz
±0.05 dB max to 26.5 GHz
(5 million cycles per section)

RF power handling capability

1 W average, 100 W peak with maximum pulse width of 10 microseconds.

Solenoid drive

Table 1-6
Solenoid
Option 024
Option 011
[a] Switching current is current per section.
[b] For switching multiple sections simultaneously, the minimum voltage is 5.5 V.

Switching speed

Maximum 20 milliseconds including settling time.
Keysight 8495D/K Operating and Service Manual
Solenoid drive
Coil vol tage
Switching current
24 V (20 to 30 V)
125 mA (at 24 V)
[b]
325 mA (at 5 V)
5 V (4.5 to 7 V)
Introduction
[a]
Nominal coil impedance
190 Ω
17 Ω
1