296 MAINTENANCE AND LUBRICATION
Electrical Grease
To prevent corrosion of the lamp socket terminals, particularly with the
clearance and marker lamp, apply a coating of electrical sealing grease, such
as Lubriplate DS-ES or TEK-519, to the socket and terminal assemblies.
CAUTION
Do not use electrical grease on any V-MAC connectors.
Circuit Protection Charts
#1
Open
#5 — 10A
Tractor Stop Lps.
#9 — 15A
CB Posts
#13 – 20A
ABS
#17 – 10A
Clutch Switch, Engine Brake, Cruise
On/Off & Set/Resume, Override
Switch, Park Brake, PTO w/o T2000,
Spare (VCU) Relay Coils
#20 – 10A
Moto Mirrors
#24 — 15A
Spare Batt./Ign.
Power
Cab Circuit Protection
#2 – 15A
Headlamps, DRL
Module, Fog
Lamps
#6 — 10A
Dome Lps.,
Courtesy Lps.
#10 — 5A
Communication
Connector (DDL),
Radio
#14
Open
#21 — 20A
Windshield Wiper
& Washer
#25 – 40A
Heater/Air
Conditioner
#3 – 15A
Park & Tail Lps.,
Marker Lamps
#7 — 10A
Ign. Switch
#11 — 15A
Battery Stud
#15 – 20A
Heated Mirrors
#18 — 10A
DPF Switch
Power/Spare
#22 — 20A
LH Window Lift
Motor
#26 — 15A
Hook-Up Lps.
#4 – 20A
Direct Lps.,
Flasher
#8 — 15A
Air Solenoid
#12 – 10A
Electric Door
Locks
#16 – 10A
Vehicle Control
Unit (VCU)
#19 — 5A
ABC Cluster
#23 — 20A
RH Window Lift
Motor
#27 — 15A
Ignition Stud