1.

Instrument

Operating temperature
range
Battery
Charger input voltage
Fuels
Display
Dimensions
Weight
Protective Casing
Conforms to
Reports

Options

2.

Probes

Standard Efficiency Probe
Insertion length
Maximum temperature
Construction
K-type thermocouple
Hose length
3.
Options
Air/Surface/Liquid Probe
Construction:
K-Type Thermocouple:
Temperature range
-10°C to 50°C (14°F to 122°F)
Rechargeable Ni-MH. Life >6
hours
115V or 230V; 50/60Hz AC
Natural Gas, LPG, Heavy Oil,
Light Oil and Coal
Back lit LCD
160 x 70 x 50mm (6.3" x 2.8" x
2")
500g (1.1 lbs.)
Rubber boot
BS7927
50 combustion analysis
25 CO room test
Protective rubber boot
IR link to PC (Windows 98 or
higher)
250mm (9.9") with
adjustable depth gauge
800°C (1472°F)
Pistol grip with stainless
steel shaft
Accuracy +/- 1°C + 0.3% of
reading
2500mm (9.9')
Handgrip with stainless steel
shaft, and protective cover
Accuracy +/- 0.3%, +/- 1°C
o
o
-50
C to +400
C (-58
o
752
F)
40
o
F to +
CO80