Optical Channels - Siemens SIMATIC NET Operating Instructions Manual

Network components/profibus, optical link module
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Connection

6.4 Optical channels

6.4
Optical channels
Information on optical channels
● You can measure the receive level of the two optical channels CH2 and CH3 using a
normal commercially available voltmeter attached to measurement sockets.
● The voltmeter can be connected and disconnected while the device is operating.
● The OLM is protected against a short circuit at the measurement sockets; data
transmission is not influenced.
● You can also read in the receive level of the two optical channels via floating, high
resistance analog inputs on a PLC.
● This allows you to do the following:
– To document the incoming optical power, for example for later measurements (aging,
– To run a good/bad check (limit value).
48
damage)
Operating Instructions, 01/2020, C79000-G8976-C270-06