9. Gas

9.1 General safety rules for the use of liquid gas
facilities
(Picture may vary somewhat from the equipment
on your camper!)
1
The gas operation pressure is
30 mbar.
Inspection of the gas facilities
Have the gas facilities checked by an expert
before the first use.
The gas facilities should be inspected by
an expert every two years. This inspection
should be documented on the inspection cer-
tificate in accordance with the German Asso-
ciation of Gas and Water Experts, worksheet
G 607, and EN 1949.
Regulator knobs, hoses and waste gas out-
lets should also be inspected.
We recommend that you replace the safety
regulator knob and hose pipes no later than
every 10 years.
The owner/operator is responsible for arrang-
ing the inspection. This also applies for vehi-
cles that are not licensed to drive on public
roads.
Installations and modifications
Located behind the kitchen drawer.
Installations and modifications may only be
conducted by an expert.
Only devices with a uniform inlet pressure of
30 mbar may be operated.
• Any change in the gas facilities requires a new
inspection by an expert and written documen-
tation of this inspection.
Regulator knobs and valves
Only use those regulator knobs custom-made
for vehicles, with a safety valve
regulator knobs are not permissible in accor-
dance with the German Association of Gas
and Water Experts, worksheet G 607, and
EN 1949. They are not sufficient to tolerate
the immense strain.
Connections on gas pressure regu-
lators are screwed on counterclock-
wise.
j
. Other
09-1