Hisense AHM-080FJFAA Operation Installation Maintenance Manual page 25

Multi-split air conditioner, water module
Table of Contents

Advertisement

No.
Code
Settings
use of water tank heat
25
for defrosting
standby time of water
26
module electric
heating
water module electric
27
heating during
defrosting
standby time of water
28
tank electric heating
upper limit of heat
29
recovery water
temperature
water pump
30
anticorrosion
water pump
31
anticorrosion running
time
water pump
32
anticorrosion running
period
Emergency moide
33
Use of floor heating for
34
defrosting
Longest continuous
running time of water
35
tank
Step 6
When the user makes the in-situ settings, some
items that needn't being set may be wrongfully
set. The following items must be the default
value. Setting error may result in inability of
normal run of water module.
Default
No. Code
Value
1
b4
inactive
2
b6
inactive
3
b7
inactive
4
d2
inactive
5
E1
inactive
6
E7
inactive
00 inactive, 01~03active
7
F3
inactive
00 inactive, 01~24active
8
F9
inactive
9
H2
inactive
10
H9
inactive
11
J4
inactive
12
J5
inactive
Default
Range
Value
inactive
inactive/active
30
1~99
inactive
inactive/active
45
01~60
40
20~45
inactive
inactive/active
0:00
0:00-23:00
6
01~07
inactive
inactive/active
inactive
inactive/active
60
02~20
Remarks
00 inactive, 01 active
00 inactive, 01 active
00 inactive, 01 active
00 inactive, 01 active
00 inactive, 01 active
00 inactive, 01active
00 inactive, 01active
00 inactive
01active
00 inactive
01active
00 inactive
01active
Minimum
Adjusting
Unit
Explanation to Functions
Unit
This function will shorten the defrosting
time and improve defrosting effect, but it
/
/
will reduce the water temperature in water
tank.
After the electric heating of water module
satisfies the conditions, it needs being
started with delayed time, for the purpose
1
min
of preventing frequent startup by electric
heating and reduce energy consumption.
This function can shorten the defrosting
/
/
time but increase electricity consumption.
When the outdoor unit has insufficient
capacity, the water tank electric heating
needs delaying the set time for startup,
1
min
for the purpose of preventing frequent
starting and reducing energy
consumption.
When heat recovery is active and reaches
1
°C
the temperature, quit from water tank heat
recovery
If not running long, start the water pump
/
/
for short-time run to prevent rusting.
1
h
water pump anticorrosion startup time
1
day
default run time is each Saturday
When the outdoor unit fails to work,
only the electric heating runs, but this
/
/
may increase electricity consumption
(for repair).
This function can shorten the defrosting
time and improve defrosting effect, but it
/
/
will reduce the floor heating water
temperature.
The longest running time of heat pump
10
m
under water tank mode.
Step 7
Press the reset key ⑤, and quit from in-situ settings.
● When the lowest water temperature guarantee
function is set as active, the electricity
consumption will increase.
● This table does not contain all wire controller set
functions. If functional setting not covered in the
table is needed, consult local dealer.
19
Remarks
00 inactive, 01 active
value indicates range of
minutes
00 inactive, 01 active
value indicates range of
minutes
value indicates temperature
range
00 inactive, 01 active
value indicates 24 hours per
day
value indicates 7 days per
week
00 inactive, 01 active
00 inactive, 01 active
set value × 10 = actual running
minutes

Hide quick links: