Step 5
Continuously press " " , " " of the time setting key
and the user may check the set codes and content for
commonly used items of in-situ settings, see details below:
No.
Code
Settings
automatic temperaure
1
adjustment
beginning time of
automatic
2
temperature
adjustment
ending time of
automatic
3
temperature
adjustment
low environmental
4
temperature
high environmental
5
temperature
set water temperature
6
of low environmental
temperature
set water temperature
7
of high environmental
temperature
8
sterilization selection
9
sterilization run time
10
sterilization run date
sterilization lasting
11
time
sterilization
12
temperature setting
electric heating of
13
water module
domestic hot water
14
(water tank mode)
15
floor heating
electric heating of
16
water tank
electric heating work
17
mode of water tank
water tank lowest
water temperature
18
guarantee during floor
heating
19
heat recovery
starting outdoor
environmental
20
temperature of
electric heating of
water module
lowest water
temperature
21
guarantee of water
tank during standby
lowest water
temperature
22
guarantee of water
tank
water temperature set
23
value of powerful
water storage
forced run of water
24
pump
Minimum
Default
Range
Adjusting
Value
inactive
inactive/active
23:00
0:00-23:00
5:00
0:00-23:00
-20
-20~5
20
6~25
44
20~55
25
25~55
inactive
inactive/active
0:00
0:00-23:00
06
01~07
10
10~60
70
50~70
active
active/inactive
inactive
inactive/active
active
active/inactive
inactive
inactive/active
ordinary
ordinary/advanced
inactive
inactive/active
inactive
inactive/active
4
-20~10
inactive
inactive/active
35
35~65
45
35~75
inactive
inactive/active
,
11
Unit
Explanation to Functions
Unit
/
/
OTC function inactive/active
1
h
beginning time of OTC
1
h
ending time of OTC
1
°C
1
°C
determine the OTC temperature curve
1
°C
1
°C
/
/
sterilization inactive/active
1
h
beginning time of sterilization
1
day
default run time is each Saturday
1
min
sterilization lasting time
1
°C
sterilization temperature
electric heating of water module
/
/
active/inactive
/
/
water tank mode inactive/active
/
/
floor heating active/inactive
/
/
Advanced mode will increase frequency
of using electric heating of water tank
/
/
and accelerate water heating speed, but
this will increase electricity
consumption.
After the setting is active, during floor
heating, start the electric heating of
/
/
water tank and ensure that the water
tank is not lower than the temperature
set by F5.
When the domestic water tank is
installed and the function is active,
/
/
during air conditioner cooling, water
module can conduct heat recovery
running.
the outdoor environmental temperature
1
°C
is higher than the set value, and electric
heating of water module can't start.
After the setting is active, the wire
controller at off state can start the
/
/
electric heating of water tank to keep the
water tank is not lower than the
temperature set by F5.
When the lowest water temperature
guarantee of water tank is active, the
water tank temperature is lower than the
1
°C
set value, and start the electric heating
to guarantee the water tank
temperature.
After power water storage is running
1
°C
and reaches the "water tank storage
water temperature", system quits.
During commissioning, forced start the
water pump for water pipe vents, or else
the air in the circulating pipe can't be
/
/
vented. After commissioning, set it as
inactive again, or else the water pump
will continuously run.
18
Remarks
00 inactive, 01 active
value indicates 24 hours per
day
value indicates 24 hours per
day
value indicates temperature
range
value indicates temperature
range
value indicates temperature
range
value indicates temperature
range
00 inactive,01active
value indicates 24 hours per
day
value indicates 7 days per
week
value indicates range of
minutes
value indicates temperature
range
00 inactive, 01 active
00 inactive, 01 active
00 inactive, 01 active
00 inactive, 01 active
00 inactive, 01 active
00 inactive, 01 active
00 inactive, 01 active
value indicates temperature
range
00 inactive, 01 active
value indicates temperature
range
value indicates temperature
range
00 inactive, 01 active