Hisense AHM-080FJFAA Operation Installation Maintenance Manual page 17

Multi-split air conditioner, water module
Table of Contents

Advertisement

5.1.3.4 Domestic Hot Water Running
Step 1
Power on, the default state of wire remote
controller will appear, and previously running
function may appear on the LCD screen. According
to the actual mounting (refer to 5.1.7 In-situ
Settings "d3"), press function key ⑥ to show
domestic hot water ; continuously press function
key ⑥ to shift the icon between floor heating and
domestic hot water until the domestic hot water is
selected.
Heating
Domestic Hot
Water
Step 2
To increase water tank temperature, press " " of
the temperature setting key ③; if it is reduced,
press " " . For domestic hot water, the highest
water outlet set temperature is 75°C, and the
lowest set temperature is 35°C.
Water Tank
Temperature Code
Actual Water
Tank Temperatur
Water Tank Set Temperature
Step 3
Press
key
⑧, the LED lamp on, and the
ON/OFF
machine begins running.
Begin Running
5.1.3.5 Powerful Water Storage Running
Step 1
Before powerful water storage, go to "5.1.7 In-situ
Settings", set the target temperature for powerful
water storage of water tank ("F6"), and also set the
"Electric Heating of Water Tank" ("d8") as active.
Step 2
At the standby state, press the hot water key ② for
3 seconds, and go to powerful water storage.
Domestic Hot Water
Electric Heater of Water Tank
Step 3
After going to powerful water storage, the domestic
hot water
and electric heater
This means powerful water storage
Step 4
After powerful water storage starts, quit from the
powerful water storage under the following 3
conditions
(1) At powerful water storage mode, press the hot
water key ② for 3 seconds.
(2) When the water tank temperature reaches the
set water temperature for powerful water
storage (5.1.7 In-situ Settings "F6").
(3) Press
key
ON/OFF
running.
5.1.3.6 Heat Recovery
Step 1
At the standby state, set "Heat Recovery" function
as active (5.1.7 In-situ Settings "E8=1") and the
domestic water tank mode active (5.1.7 In-situ
Settings "d3=1"). At the indoor air conditioner
cooling mode, it automatically turns to heat recovery
function.
Heating
flashes at 1 Hz
Domestic Hot
Water
flashes at 1 Hz
11
at 1 Hz.
is running.
⑧ , the machine stops