3. The controls are mounted to the evaporator
cover
(Figure
2-56). Remove the control
knobs and nuts. The controls will pull off the
mounting bracket.
NOTE:
It is possible to reinstall the control 180
in the wrong position. Be sure the control readout
is proper.
4. Refrigerator Control - The cap tube of the
refrigerator control is routed through a chan-
nel formed by the evaporator fins. Pull the
control bulb from the channel
When reinstalling the control, follow the
instructions that are supplied with the replace-
ment control.
5. Freezer Control -The freezer control cap tube
is routed to the back of the freezer, through a
plastic tube from the refrigerator to the freezer
area (Figures
2-58
control bulb and pull back through. When
reinstalling, push the bulb through the tube,
then coil the excess bulb at the outlet.
CONTROLS - MODELS 532, 542, 561
WARNING
Always disconnect electrical power to equip-
ment before attempting repairs.
Refrigerator Control
For access to the refrigerator control, use the fol-
lowing procedure:
1. Remove the overhead light shield by grasping
the back edge of the shield and pulling for-
ward to release, then drop the front edge out
of the channel.
(Figure
2. Remove the two screws from the air diffuser
and lift out
(Figure
cover out at the top and lift off of the posts at
the bottom.
3. The refrigerator control is mounted to the
evaporator cover
control knob and two nuts. The control will
pull off the mounting bracket.
(Figure
2-57).
& 2-59). Straighten the
2-54).
2-55). Tilt the evaporator
(Figure
2-56). Remove the
COMPONENT INFORMATION
Model 511, 550
°
Figure 2-57. Refrigerator Control Routing
Model 511, 550
Refrigerator
Control
Figure 2-58. Controls Location and Routing
Model 511, 550
Figure 2-59. Freezer Control
2-21
Freezer
Control
Freezer Control
Sensor Housing

Advertisement