exceeding the specified limits during the following data collection session according the
schedule only, but the modem will send that data immediately too. Every following message,
which will form according to the data collection period, also will have sent immediately until
the current value measurements are back in range.
With the "Confirmed uplinks" option turned on, the device will send the next packet
only after receiving a confirmation of the delivery of the previous one. If such confirmation
has not received after the fulfilled in the settings uplink number of transmissions, device
completes the communication session until the next one according to the schedule. In this
case, the device continues to collect data according to the data collection period and store it
in memory. Non-transmitted packets remain in the device memory until the next
communication session.
With the "Confirmed uplinks" option turned off, the device just sends all accumulated
packets to the network in order from the earliest to the latest. There are no checks of package
delivery in this mode. There are no non-transmitted messages in the device memory.
The internal clock is set automatically when device connected to the "Vega LoRaWAN
Configurator" via USB, also adjustable via LoRaWAN.

FUNCTIONAL

Vega TP-11 converter can be either of class A or class C (LoRaWAN classification) and
has the following features:
o Automatic change from A class to C class when powered from an external
power supply
o ADR support (Adaptive Data Rate)
o Sending of confirmed packets (configurable)
o Extra communication in case of security inputs actuation
o Extra communication in case of current value measurements are out of specified
range
o Temperature measurement by the internal temperature sensor
o Charge measuring of the built-in battery (%)
o Ability to configure security input triggering on short, open or both cases
o Ability to set different data collection period for case of current value
measurements are out of specified range
o Immediately data sending at moment of message forming for case of current
value measurements are out of specified range
6
Vega TP-11 / User Manual
Revision 09 – 08 April 2020