Advanced Configuration
message is to be sent from the camera as a result of an alarm, it is necessary to define Message
Systems and set up Notification Lists (refer to
In general, each Alarm Rule describes an alarm Source and a single alarm Action. For the FB-
Series ID camera, the source of the alarm typically will be internal from the video analytics, although
it is also possible for the camera to receive alarms from another camera or device/server on the
network (such as a radar server, input/output server, ground sensor, fence system, or other security
sensor).
Alarm Source: When the source of alarms are internal, for example, from Video Analytics or GPIO
Input, the Alarm Source Server IP Address is set to the localhost value of 127.0.0.1 and the TCP
port is the default 1001. For internal alarms, the FB-Series ID camera Alarm Source Device ID is set
to 0.
The Alarm Source Device Type is chosen from a pull down
menu; not all options are available for a specific camera or
installation.
When the alarm source is Video Analytics the Alarm ID
corresponds to the area or tripwire (1-8), as configured in the
Setup menu. The Alarm ID is set sequentially during the
setup for each alarm source. Refer to
Setup—FB-Series ID Only, pg.
When the alarm source is from the GPIO Input the Alarm ID
is changed to the Input ID and can be set to 0 or 1 (recall that inputs are I/O 0 and I/O 1).
427-1065-00-12 Revision 130
Services Menu, pg.
Video Analytics
37.
November 2019
This document does not contain any export-controlled information.
22).