Advanced Configuration
Check Calibration
1. Click the
icon and set Analytics Enabled to Yes.
2. Set Show Tracking to Show Triggered then check the
Lines box.
3. Click Save.
4. Have subjects (person, car, truck, etc) enter the area or
cross the tripwire at various distances from the camera.
The boxes should be classified correctly and the direc-
tion across tripwires should be as expected.
The image below shows a classified human box and tracking
line in a detection region. The box is white indicating an
alarm condition has occurred.