High Performance RA-RFM RI-RFM-008B

2.1 Recommended Operating Conditions

Symbol
V_VSP
Supply voltage of transmitter power stage
I_VSP
Current consumption of transmitter power stage - refer to the
formula below
P_VSP
Peak pulse power input to transmitter power stage (I_VSP *
V_VSP * Duty Cycle)
V_ANT
Antenna resonance voltage
Antenna resonance voltage (Pulse width setting ≤ 25%)
V_ANT-25
V_ANT-
Minimum antenna resonance voltage for correct operation of ATI
ATI
V_VSL
Supply voltage input for logic part
I_VD
External current load on internal regulated logic supply voltage
output
T_oper
Operating free-air temperature range
T_store
Storage temperature range
CAUTION:
Exceeding recommended maximum ratings may lead to
permanent damage of the RA-RFM.
The RA-RFM must not be operated in continuous transmit
mode when operated at full power output.
Install suitable heatsinks when operating the RA-RFM at
pulse widths smaller than 50%.
Table 9 shows the recommended operating conditions.
Table 9: Operating Conditions
Parameter
Note:
Free-air temperature is the air temperature immediately surrounding
the RA-RFM module. If the module is incorporated into a housing, it
must be guaranteed by proper design or cooling that the internal
temperature does not exceed the recommended operating conditions.
20
February 2002
min.
typ.
max.
7.0
14.0
24.0
V DC
1.0
2.0
Apeak
24
W
250
380
Vpeak
200
Vpeak
25
Vpeak
7.0
24.0
V DC
1.0
mA
-25
+70
° C
-40
+85
° C