Acromag BusWorks XT Series User Manual

Ac/dc input interface board six channel active low analog or digital inputs six open-drain outputs (active-low)
Hide thumbs Also See for BusWorks XT Series:

Advertisement

Quick Links

Acromag BusWorks XT Series User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BusWorks XT Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Acromag BusWorks XT Series

  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2 Six Open‐Drain Outputs (Active‐Low) USER’S MANUAL ACROMAG INCORPORATED Tel: (248) 295‐0880 30765 South Wixom Road Fax: (248) 624‐9234 Wixom, MI 48393‐2417 U.S.A. email: sales@acromag.com Copyright 2014, Acromag, Inc., Printed in the USA. 8500‐961J Data and specifications are subject to change without notice.
  • Page 3: Table Of Contents

    Acromag, that this is your responsibility. The information of this manual may change without notice. Acromag makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Further, Acromag assumes no responsibility for any errors that may appear in this manual and makes no commitment to update, or keep current, the information contained in this manual.
  • Page 4: Description

    This module is designed for high‐density mounting on 35mm, T‐type DIN rails. Modules may be mounted side‐by‐side on 22.5mm centers and connected together for modular expansion and shared power along the DIN rail. Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 5: Mechanical Dimensions

    DIN rail clip and use it as a lever to force the DIN rail spring clip down while pulling the bottom of the module outward until it disengages from the rail. Tilt the module upward to lift it from the rail. Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 6: Electrical Connections

    (use 0.5‐0.6nM torque). Since common mode voltages can exist on I/O wiring, adequate wire insulation should be used and proper wiring practices followed. As a rule, I/O wires are normally separated from power and network wiring for safety, as well as for low noise pickup. Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 7: Power Connections

    DIN rail bus when coupled to the DIN rail bus connector (Acromag Model 1005‐063) and a bus terminal block (Acromag 1005‐220 or 1005‐ 221). This optional method can allow several modules to share a single power supply without wiring to each individually.
  • Page 8 Important – End Stops: If this module uses the optionally powered (or redundantly powered) via the DIN rail bus for hazardous location installations (Class I, Division 2 or ATEX Zone 2) it must use two end stops (Acromag 1027‐222) to secure the terminal block and module (not shown).
  • Page 9: Analog Input Connections

    (return), and include 1K pull‐ups to +6VDC. Outputs will switch loads up to 32VDC and 150mA each. Observe proper polarity when making output connections. Refer to the following figures to wire the outputs of this module. Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 10 INPUT 150mA MAX LAMP 13 14 15 16 19 20 V LEVEL IS SET PER COIL 0-32 VDC REQUIREMENT AND MUST 40WV BE FROM 5V TO 48V ANALOG 17 18 21 22 XTA-AC120-6 SIMPLIFIED CHANNEL Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 11: Earth Ground Connections

    See the Electrical Connections Drawings for I/O and power ground connections. Avoid inadvertent connections to earth ground at other points than those indicated, as this could drive ground loops and negatively affect operation. Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 12: Block Diagram

    12–32VDC. A bus connector is provided to allow optional/redundant power. Bus power and terminal power connections are diode coupled to allow simultaneous powering. TVS diodes and bypass capacitors protect the input, output, and power circuits from high voltage transients. Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 13: Troubleshooting

    Acromag for repair, or replacement. Acromag has automated test equipment that thoroughly checks and verifies the performance of each module. Please refer to Acromag’s Service Policy and Warranty Bulletins on our web site, or contact Acromag for complete details on how to obtain repair or replacement.
  • Page 14: Specifications

    Use voltage protection when switching inductive loads (place a reverse shunt diode across inductive loads to dissipate energy that develops during switching). Output “OFF” Leakage Current: 1µA typical, 50µA maximum (mosfet only, 25°C, 32VDC). Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 15: Power

    Circuit Board: Military grade fire‐retardant epoxy glass per IPC‐4101/98. DIN‐Rail Mounting: Unit is normally mounted to 35x15mm, T‐type DIN rails. Refer to the DIN Rail Mounting & Removal section for more details. Shipping Weight: 0.5 pounds (0.22 Kg) packed. Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 16: Environmental

    2, as defined in EN 60664‐1. The equipment shall be installed in an enclosure that provides a degree of protection not less than IP 54 and only accessible with the use of a tool in accordance with EN 60079‐15. Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 17: Reliability Prediction

    • Page 13 Digital Outputs (Description was +6V) • Page 14 Digital Outputs (Output Pull‐ups was +6VDC) • Page 15 Environmental (Storage Temperature was ‐40°C to +70°C) • Page 15 Reliability Prediction (MTBF / FIT was TBD) Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 18 Added ATEX symbols / statements. 21‐JUL‐2016 CAP/MJO Corrected Input Voltage Specifications. 22‐AUG‐2016 CAP/MJO Corrected “Circuit Board” specification. Removed reference to XTA‐240‐6 under the “Getting Started 23 MAR 2017 CAP/MJO Description”, as there is no such model. Acromag, Inc. Tel: 248‐295‐0880 http://www.acromag.com...
  • Page 19 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...

This manual is also suitable for:

Busworks xta-120v-6

Table of Contents