Option
[109]
Enable Vir.Mas-
ter
[110]
Start homing
[111]
Activate touch
[112]
Relative posi-
tion
[113]
Enable refer-
ence
[114]
Sync. to Pos.
Mode
24 | Danfoss A/S © 2020.01
Function
This option is available only with IMC software version 48.XX.
Enable signal for the virtual master function. Only applicable when option [10] Synchronization is selec-
ted in parameter 1-00 Configuration Mode.
This option is available only with IMC software version 48.XX.
Starts the homing function selected in parameter 17-80 Homing Function. Must remain high until homing
is done, otherwise homing is aborted.
This option is available only with IMC software version 48.XX.
Activates the monitoring of the touch sensor input.
This option is available only with IMC software version 48.XX.
This option selects between absolute and relative positioning. The option is valid for the next position-
ing command.
This option is available only with IMC software version 48.XX.
Positioning mode: The drive activates the selected positioning type and target and starts the motion to-
wards the new target. The motion starts either immediately or when active positioning is completed, de-
pending on settings of parameter 17-90 Absolute Position Mode and parameter 17-91 Relative Position
Mode. Synchronization mode: High signal locks the actual follower position to the actual master position.
The follower starts and catches up with the master. Low signal stops the synchronization and the follow-
er makes a controlled stop.
This option is available only with IMC software version 48.XX.
Select positioning in synchronization mode.